Rite‑Hite
®
Installation/Service/Owner's Manual
FasTrax
®
XL
Publication:
AMEN00316 2020-07-06
11
INSTALLATION
Mounting Methods
Continued
Acceptable Fasteners
Threaded rods can be used and cut to length in the field to suit
the application
Hex head bolts can be used, but length
must be determined ahead of time to ensure
fasteners will work with application
Wall Sleeve
3/8in [M10] ID Ø
Backer Plate
1/8in x 6in [3mm x 152mm] Ø
Typical Fastener Spacing
Lower track fasteners
3/8in [M10] minimum
Header
Lower track
Header fasteners
3/8in [M10] minimum,
2 through bolts required
Walls constructed of wood, dry wall, stone block, or
insulation require further jamb preparation
The fastening method, is the responsibility of the installer
It requires the door to remain attached to the wall if, for
example, a door fails to open when a vehicle approaches
and impacts the non-mounted side Lower tracks on doors
are required to be through bolted a minimum of every
4ft [1.2m] with 3/8in [M10] minimum fasteners filling in
Wall sleeves and backer plates may be required if wall
crushes when fasteners are tightened
Backer plates (if used) must be clean and either painted
or a non-ferrous material
Figure 5
Figure 6
Summary of Contents for FasTrax XL
Page 9: ...Rite Hite Installation Service Owner s Manual FasTrax XL Publication AMEN00316 2020 07 06 9...
Page 89: ...Rite Hite Installation Service Owner s Manual FasTrax XL Publication AMEN00316 2020 07 06 89...
Page 90: ...FasTrax XL Installation Service Owner s Manual Rite Hite 90 Publication AMEN00316 2020 07 06...
Page 91: ...Rite Hite Installation Service Owner s Manual FasTrax XL Publication AMEN00316 2020 07 06 91...