WARNING
Code
De
fi
ni on
Remedy
03
Power
interrup on
during
Bath
Fill
(Water
will
not
fl
ow
when
power
returns).
Turn
o
ff
all
hot
water
taps.
Press
ON/OFF
twice.
10
Air
Supply
or
Exhaust
Blockage
Check
that
nothing
is
blocking
the
fl
ue
inlet
or
exhaust.
Check
all
vent
components
for
proper
connec ons.
licensed
professional
only
Ensure
approved
ven ng
materials
are
being
used.
Ensure
vent
length
is
within
limits.
Verify
dip
switches
are
set
properly.
Check
fan
for
blockage.
11
No
Igni on
(heater
not
turning
on)
Check
that
the
gas
is
turned
on
at
the
water
heater,
gas
meter,
or
cylinder.
If
the
system
is
propane,
make
sure
that
gas
is
in
the
tank.
Ensure
appliance
is
properly
grounded.
licensed
professional
only
Ensure
gas
type
and
pressure
is
correct.
Ensure
gas
line,
meter,
and/or
regulator
is
sized
properly.
Bleed
all
air
from
gas
lines.
Verify
dip
switches
are
set
properly.
Ensure
igniter
is
opera onal.
Check
igniter
wiring
harness
for
damage.
Check
gas
solenoid
valves
for
open
or
short
circuits.
Remove
burner
cover
and
ensure
all
burners
are
properly
seated.
Remove
burner
plate
and
inspect
burner
surface
for
condensa on
or
debris.
Check
the
ground
wire
for
the
PC
board.
12
No
Flame
Check
that
the
gas
is
turned
on
at
the
water
heater,
gas
meter,
or
cylinder.
Check
for
obstruc ons
in
the
fl
ue
outlet.
If
the
system
is
propane,
make
sure
that
gas
is
in
the
tank.
licensed
professional
only
Ensure
gas
line,
meter,
and/or
regulator
is
sized
properly.
Ensure
gas
type
and
pressure
is
correct.
Bleed
all
air
from
gas
lines.
Ensure
proper
ven ng
material
was
installed.
Ensure
condensa on
collar
was
installed
properly.
Ensure
vent
length
is
within
limits.
Verify
dip
switches
are
set
properly.
Check
power
supply
for
loose
connec ons.
Check
power
supply
for
proper
voltage
and
voltage
drops.
Ensure
fl
ame
rod
wire
is
connected.
Check
fl
ame
rod
for
carbon
build
‐
up.
Disconnect
and
reconnect
all
wiring
harnesses
on
unit
and
PC
board.
Check
for
DC
shorts
at
components.
Check
gas
solenoid
valves
for
open
or
short
circuits.
Remove
burner
plate
and
inspect
burner
surface
for
condensa on
or
debris.
14
Thermal
Fuse
has
ac vated
Check
for
restric ons
in
air
fl
ow
around
unit
and
vent
terminal.
licensed
professional
only
Check
gas
type
of
unit
and
ensure
it
matches
gas
type
being
used.
Check
for
low
water
fl
ow
in
a
circula ng
system
causing
short
‐
cycling.
Ensure
dip
switches
are
set
to
the
proper
posi on.
Check
for
foreign
materials
in
combus on
chamber
and/or
exhaust
piping.
Check
heat
exchanger
for
cracks
and/or
separa ons.
Check
heat
exchanger
surface
for
hot
spots
which
indicate
blockage
due
to
scale
build
‐
up.
Refer
to
instruc ons
in
manual
for
fl
ushing
heat
exchanger.
Hard
water
must
be
treated
to
prevent
scale
build
up
or
damage
to
the
heat
exchanger.
Measure
resistance
of
safety
circuit.
Ensure
high
fi
re
and
low
fi
re
manifold
pressure
is
correct.
Check
for
improper
conversion
of
product.
16
Over
Temperature
Warning
(safety
shutdown
because
unit
is
too
hot)
Check
for
restric ons
in
air
fl
ow
around
unit
and
vent
terminal.
licensed
professional
only
Check
for
low
water
fl
ow
in
a
circula ng
system
causing
short
‐
cycling.
Check
for
foreign
materials
in
combus on
chamber
and/or
exhaust
piping.
Check
for
blockage
in
the
heat
exchanger.
Summary of Contents for . REU-VC2025FFU-US
Page 27: ...Value Series Manual 27 Ladder Diagram ...
Page 77: ...Value Series Manual 77 ...
Page 78: ...78 Value Series Manual ...
Page 79: ...Value Series Manual 79 ...