Do
not
rely
on
the
gas
or
water
piping
to
ground
the
water
heater.
A
screw
is
provided
in
the
junc on
box
for
the
grounding
connec on.
The
water
heater
requires
120
VAC,
60
Hz
power
from
a
properly
grounded
circuit.
If
using
the
5
foot
long
power
cord,
plug
it
into
a
standard
3
prong
120
VAC,
60
Hz
properly
grounded
wall
outlet.
On
outdoor
models,
a
disconnect
switch
must
be
provided
and
installed
for
the
incoming
120
VAC
power.
It
should
be
a
type
that
is
suitable
for
outdoor
use.
Check
the
Na onal
Electrical
Code,
ANSI/NFPA
70
and
your
local
codes
for
a
proper
switch
type
to
use
in
your
area.
The
wiring
diagram
is
located
on
the
Technical
Sheet
a ached
to
the
inside
of
the
front
cover.
WARNING
Do
not
use
an
extension
cord
or
an
adapter
plug
with
this
appliance.
The
water
heater
must
be
electrically
grounded
in
accordance
with
local
codes
and
ordinances
or,
in
the
absence
of
local
codes,
in
accordance
with
the
Na onal
Electrical
Code,
ANSI/NFPA
No.
70.
Indoor
water
heaters
are
equipped
with
a
three
‐
prong
(grounding)
plug
for
your
protec on
against
shock
hazard
and
should
be
plugged
directly
into
a
properly
grounded
three
‐
prong
receptacle.
Do
not
cut
or
remove
the
grounding
terminal
from
this
plug.
Checklist
for
Gas
and
Electricity
□
A
manual
gas
control
valve
is
placed
in
the
gas
line
to
the
water
heater.
□
Check
the
gas
lines
and
connec ons
for
leaks.
□
Con
fi
rm
that
the
gas
inlet
pressure
is
within
limits.
□
Con
fi
rm
that
the
water
heater
is
rated
for
the
gas
type
supplied.
□
Con
fi
rm
that
the
electricity
is
supplied
from
120
VAC,
60
Hz
power
source
and
is
in
a
properly
grounded
circuit.
□
An
extension
cord
or
an
adapter
plug
has
not
been
used
with
the
water
heater.
□
For
indoor
models
verify
that
switch
No.
1
in
the
SW1
DIP
switch
(tan
switches)
has
been
adjusted
for
vent
length
if
necessary.
Refer
to
the
sec on
on
Maximum
Vent
Length.
Adjust
for
High
Al tude
For
the
V75i/e
,
on
the
SW1
DIP
switch
(tan
switches),
set
switches
2
and
3
to
the
values
shown
in
table
below
for
your
al tude.
The
default
se ng
for
the
appliance
is
0
‐
2000
(0
‐
610
m)
with
switches
No.
2
and
No.
3
in
the
OFF
posi on.
When
the
DIP
switch
is
adjusted,
it
is
not
necessary
to
adjust
the
gas
pressure
se ng
for
high
al tude.
The
V65i/e
is
not
approved
for
high
al tude
opera on.
Al tude
SW1
Switch
No.
2
SW1
Switch
No.
3
0
‐
2000
(0
‐
610
m)
OFF
OFF
2001
‐
5200
(610
‐
1585
m)
OFF
ON
5201
‐
7700
(1585
‐
2347
m)
ON
OFF
7701
‐
10200
(2347
‐
3109
m)
ON
ON
Adjust
for
Vent
Length
(indoor
models
only)
Adjust
switch
No.
1
in
the
SW1
DIP
switch
(tan
switches)
if
required.
Refer
to
the
sec on
“Maximum
vent
length”.