Condensate
(indoor
models
only)
Condensate
forma on
can
occur
in
high
e
ffi
ciency
direct
vent
appliances.
Without
proper
drainage
condensate
will
damage
the
heat
exchanger.
To
prevent
condensate
damage
follow
these
instruc ons.
DO
NOT
•
Do
not
allow
condensate
to
enter
the
water
heater.
•
Do
not
connect
the
condensate
drain
pipe
directly
to
the
rain
sewer.
•
Do
not
connect
the
condensate
drain
line
with
an
air
condi oning
evaporator
coil
drain.
MUST
DO
•
Use
only
vent
that
is
approved
and
iden
fi
ed
as
acceptable
for
your
par cular
model.
•
For
ver cal
termina ons,
install
a
condensate
drain
and
trap
as
close
as
possible
to
the
appliance.
•
Slope
the
ven ng
toward
the
appliance
according
to
the
vent
manufacturers
installa on
instruc ons.
•
All
condensate
must
drain
and
be
disposed
of
according
to
local
codes.
•
Use
only
PVC
or
CPVC
pipe
for
the
condensate
drain
line.
•
The
condensate
drain
pipe
(along
its
en re
length)
must
be
at
least
the
same
diameter
as
the
drain
line,
(5/8
inch
NPT).
•
The
end
of
the
condensate
drain
pipe
should
be
open
to
the
atmosphere.
The
end
should
not
be
under
water
or
other
substances.
•
To
minimize
freezing
of
the
condensate,
run
the
condensate
drain
line
through
an
interior
wall
or
between
insula on
and
an
interior
wall.
•
The
condensate
collector
should
be
used
for
all
hydronic
hea ng
applica ons.
Checklist
for
Ven ng
and
Condensate
(indoor
models
only)
□
Verify
proper
clearances
around
the
vents
and
air
intakes.
□
Ensure
you
have
used
the
correct
ven ng
products
for
the
model
installed
and
that
you
have
completely
followed
the
ven ng
manufacturer’s
installa on
instruc ons
and
these
installa on
instruc ons.
□
Verify
that
the
vent
pipe
has
a
downward
slope
or
grade
to
the
outside
of
1/4
inch
per
foot
(1.2
°
)
OR
if
the
vent
pipe
is
sloped
toward
the
water
heater
(as
some
local
codes
require),
that
a
condensate
collector
is
installed
to
allow
condensa on
to
drain
away
from
the
water
heater
to
a
proper
drain
source.
□
Verify
that
condensate
will
not
be
allowed
to
drain
back
into
the
water
heater.
□
Verify
that
the
vent
system
does
not
exceed
the
maximum
length
for
the
number
of
elbows
used.
INFORMATION
•
A
condensate
trap
is
available,
P/N
222053.
•
Regions
of
cold
climate
will
create
more
condensate
in
the
vent
system.
The
condensate
collector
should
be
used
in
cold
climates.
•
The
condensate
drain
pipe
should
be
as
short
as
possible
and
have
a
downward
pitch.