RIGOL
User’s Guide for DSA1000 Series
2-83
If Delta, Delta Pair, or Span Pair is selected, the center frequency will be set
to the frequency at which the Delta Marker is located.
The function is invalid in Zero span mode.
2.5.2.2
Mkr->Step
Sets the center frequency step of the analyzer based on the frequency of the current
marker.
If Normal is selected, the center frequency step will be set to the frequency of
current marker.
If Delta, Delta Pair or Span Pair is selected, the center frequency step will be
set to the frequency at which the Delta Marker is located.
The function is invalid in Zero span mode.
2.5.2.3
Mkr->Start
Sets the start frequency of the analyzer based on the frequency of the current marker.
If Normal is selected, the start frequency will be set to the frequency of the
current marker.
If Delta, Delta Pair or Span Pair is selected, the start frequency will be set to
the frequency at which the Delta Marker is located.
The function is invalid in Zero span mode.
2.5.2.4
Mkr->Stop
Sets the stop frequency of the analyzer based on the frequency of the current marker.
If Normal is selected, the stop frequency will be set to the frequency of the
current marker.
If Delta, Delta Pair or Span Pair is selected, the stop frequency will be set to
the frequency at which the Delta Marker is located.
The function is invalid in Zero span mode.