RIGOL
User’s Guide for DSA1000 Series
3-31
-
Press TOI Span and enter 2 MHz.
3.
Measurement result
The measurement results shown in the lower window are:
Freq
dBm
dBc
Intercept
Base Lower
100 MHz
-5.7 dBm
0
---
Base Upper
100.2 MHz -5.65 dBm
0.05
---
3rd Order Lower
99.8 MHz
-60.16 dBm
-54.46
21.53
3rd Order Upper
100.4 MHz -60.93 dBm
-55.23
21.99
See figure below.
Figure 3-15 Use TOI function to measure TOI distortion