7
ENGLISH
Twin pipes (ø 80 mm)
(Fig. 16)
The combustion air suction pipe should be selected from the two inputs,
remove the closing plug fi xed with the screws and fi x the specifi c air
defl ector.
Position the adaptor on the fl ue gases pipe so that the Ø 60 pipe goes fully
up against the fl ue gases turret of the boiler.
- Once positioned, make sure that the 4 notches
(A)
on the fl ange connect
to the groove
(B)
on the Ø 100 of the adaptor.
- Fully tighten the screws
(C)
that tighten the two locking terminals of the
fl ange so the adaptor itself is restrained.
If the Ø 60-100 to Ø 80-80 splitter kit is used instead of the twin pipe system,
there is a loss in the maximum lengths as shown in the table.
Place the splitter so that the Ø 60 pipe goes fully up against the fl ue gases
turret of the boiler.
Once positioned, make sure that the 4 notches
(A)
on the fl ange connect to
the groove
(B)
on the Ø 100 of the splitter.
Fully tighten the screws
(C)
that tighten the two locking terminals of the
fl ange so the adaptor itself is restrained.
Ø50
Ø60
Ø80
Loss of length (m)
0.5
1.2
5.5 for flue gases pipe
7.5 for air pipe
Coaxial pipes (ø 80-125 mm)
(Fig. 17)
- Place the adaptor vertical attachment so that the Ø 60 pipe goes fully up
against the fl ue gases turret of the boiler.
- Once positioned, make sure that the 4 notches
(A)
on the fl ange connect
to the groove
(B)
on the Ø 100 of the adaptor.
- Fully tighten the screws
(C)
that tighten the two locking terminals of the
fl ange so the adaptor itself is restrained.
- Then fi t the Ø 80-125 adaptor kit on the vertical fi tting
Twin pipes with Ø 80 pipework Ø50 - Ø60 - Ø80)
(Fig. 18)
Thanks to the boiler characteristics, a Ø80 fl ue gas exhaust pipe can be
connected to the Ø50 - Ø60 - Ø80 piping ranges.
b
For the pipe, you are advised to make a project calculation in order
to respect the relevant regulations in force.
The table shows the standard confi gurations allowed.
Table of standard pipe confi guration (*)
Air suction
1 Bend 90° Ø 80
4.5m pipe Ø80
Flue gas discharge
1 Bend 90° Ø 80
4.5m pipe Ø80
Reduction from Ø80 to Ø50 from Ø80 to Ø60
Flue base bend 90°, Ø50 or Ø60 or Ø80
For ducting pipe lengths see table
(*) Use fl ue gas system accessories made of plastic (PP) for condensing
boilers: Ø50 and Ø80 class H1 and Ø60 class P1.
The boilers are factory set to:
25 KIS:
6,200 r.p.m. in heating mode and 7.600 in domestic hot water mode
and the maximum attainable length is 5m for the Ø 50 pipe, 18 m for the Ø
60 pipe and 98 m for the Ø 80 pipe.
30 KIS:
5,800 rpm in heating mode and 6,900 in domestic hot water mode,
and the maximum length that can be reached is 2m for the Ø50 and 11 m
for the Ø60 pipe and 53 m for the Ø80 pipe.
35 KIS:
6,900 rpm in heating mode and 7.800 in domestic hot water mode,
and the maximum length that can be reached is 2m for the Ø50 pipe and 11
m for the Ø60 pipe and 57 m for the Ø80 pipe.
Should greater lengths be required, compensate the pressure drop with
an increase in the r.p.m.of the fan, as shown in the adjustments table, to
provide the rated heat input.
b
The minimum calibration should not be modifi ed.
Table of adjustments
Fan rotations
r.p.m.
Pipework ducts
ΔP at
boiler
outlet
Maximum length [m]
Heating
DHW
Ø 50
Ø 60
Ø 80
Pa
25 KIS
6200
7600
5
18
98
174
6300
7700
7 (*)
23 (*)
125 (*)
213
6400
7800
9 (*)
28 (*)
153 (*)
253
6,500
7900
11 (*)
33 (*)
181 (*)
292
6600
8,000
13 (*)
38 (*)
208 (*)
332
6700
8100
15 (*)
43 (*)
236 (*)
371
6800
8200
17 (*)
48 (*)
263 (*)
410
6900
8300
19 (*)
53 (*)
291 (*)
450
7,000
8400
22 (*)
58 (*)
319 (*)
489
7100
8,500
24 (*)
63 (*)
346 (*)
528
30 KIS
5800
6900
2
11
53
150
5900
7,000
4
15
73
189
6000
7100
5 (*)
19 (*)
93 (*)
229
6100
7200
7 (*)
24 (*)
113 (*)
268
6200
7300
9 (*)
28 (*)
133 (*)
308
6300
7400
10 (*)
32 (*)
153 (*)
347
6400
7500
12 (*)
36 (*)
173 (*)
386
6,500
7600
14 (*)
40 (*)
193 (*)
426
6600
7700
16 (*)
44 (*)
214 (*)
465
6700
7800
17 (*)
49 (*)
234 (*)
504
35 KIS
6900
7800
2
11
57
190
7,000
7900
3 (*)
15 (*)
75 (*)
229
7100
8,000
4 (*)
19 (*)
93 (*)
269
7200
8100
6 (*)
22 (*)
112 (*)
308
7300
8200
7 (*)
26 (*)
130 (*)
348
7400
8300
9 (*)
30 (*)
148 (*)
387
7500
8400
10 (*)
33 (*)
166 (*)
426
7600
8,500
12 (*)
37 (*)
184 (*)
466
7700
8600
13 (*)
40 (*)
202 (*)
505
7800
8700
15 (*)
44 (*)
220 (*)
544
(*) Maximum length that can be installed ONLY with class H1 discharge
pipes.
The Ø50 or Ø60 or Ø80 confi gurations contain Lab test data. In the event of
installations that diff er from the indications in the “standard confi gurations”
and “adjustments” tables, refer to the equivalent linear lengths below.
b
In any case, the maximum lengths declared in the booklet are guaranteed,
and it is essential not to exceed them.
COMPONENT Ø 50
Linear equivalent in metres Ø80 (m)
Bend 45° Ø 50
12.3
Bend 90° Ø 50
19.6
Extension 0.5m Ø 50
6.1
Extension 1.0m Ø 50
13.5
Extension 2.0m Ø 50
29.5
COMPONENT Ø 60
Linear equivalent in metres Ø80 (m)
Bend 45° Ø 60
5
Bend 90° Ø 60
8
Extension 0.5m Ø 60
2.5
Extension 1.0m Ø 60
5.5
Extension 2.0m Ø 60
12