22
FAMILY CX
5.7
“Pre-heating” function
it is possible to access the PRE-HEATING function selecting SET on the
main screen of the REC10.
Setting PRE-HEATING = 1 the boiler's domestic hot water function
activates. This function keeps the water in the domestic hot water
exchanger hot, to reduce standby times when a request is made. When the
pre-heating function is enabled, the symbol P comes on with a steady light
at the top with respect to the hot water icon. During burner ignition following
a pre-heating request, the symbol P starts flashing.
However, setting the parameter PRE-HEATING = 2 activates the Touch&Go
function, the boiler carries out, only if necessary, just one pre-heating cycle
after each take of domestic hot water.
To deactivate the pre-heating function, set the parameter to PRE-HEATING
= 0, the symbol "P" switches off.
The function is not active when the boiler is OFF.
SET
HEATING
DHW
PREHEATING
5.8
Boiler start-up
If there is a room thermostat or a programming timer, or the REC10
MASTER is set as an ambient regulator, it is necessary that these are
on and that they have been adjusted to a temperature higher than the
ambient temperature so that the boiler switches on.
The boiler will be in standby until the burner switches on following a heat
request. The display shows “ ” to indicate the presence of a fl ame.
42
°C
MENU
STATE
SET
INFO
PLANT
HOT WATER TEMPERATURE
FRI
1.3
bar
18/05/2013
12:17
The boiler will be in function until the selected temperature is reached,
afterwards it will be in “standby” again keeping the outlet temperature
displayed.
If faults arise in ignition or operations, the boiler performs a “SAFETY
STOP”: the triangle signalling faults will fl ash on the REC10 . To identify the
fault codes and to reset the appliance, see the section "Signals and faults".
E010
PRESS OK TO RESET
FLAME LOCKOUT
5.9
Reset function
In the event of a lockout, it is possible to try and reset normal operations by
pressing “
ENTER
” on the REC10 when the fault message is displayed to
reset the alarm in progress.
b
If the release attempts do not restart the boiler, contact your local
Technical Assistance Centre.
5.10 Screed heater function
For a low temperature system the boiler has a "screed heater" function that
can be activated in the following way:
- set the status of the boiler to OFF
OFF
HOT WATER ONLY
HEATING AND HOT WATER
BOILER
- access the technical parameters as explained in the section“ Accessing
the technical parameters”.
- select SCREED HEATER with the "
UP
" and "
DOWN
" keys , confirming
the selection (Note: SCREED HEATER is not available if the boiler is not
OFF)
INSTALLER
RANGE RATED
CALIBRATION
COMBUSTION ANALYSIS
SCREED HEATING
EXHAUST PROBE RESET
TECHNICAL
×
- select START FUNCTION with the "
UP
" and "
DOWN
" keys , confirming
the selection to activate it
- select STOP FUNCTION with the "
UP
" and "
DOWN
" keys , confirming
the selection to deactivate it.
FUNCTION ACTIVE
FUNCTION NOT ACTIVE
SCREED HEATING
INSTALLER
The screed heater function, when active, is signalled on the main screen by
the scrolling message at the bottom of the SCREED HEATER FUNCTION
IN PROGRESS - DELIVERY TEMPERATURE page.
The “screed heater” function lasts 168 hours (7 days) during which, in the
zones configured as low temperature, a heating request is simulated with
an initial zone outlet of 20°C, then increased in line with the table on the
side.
Accessing the INFO menu from the main page of the REC10 it is possible
to display the TIME FUNC SCREED HEATER value regarding the number
of hours since the start of the function.