10
FAMILY CX
This icon indicates that the OFF operating status mode has been set. Each ignition request is ignored except for the anti-freeze function. The pump
anti-lock, 3-way valve and anti-freeze function remain active.
This icon indicates that WINTER mode has been selected (HEATING function enabled). If a heating request from the main zone is in progress, the
icon will be flashing.
This icon indicates that the circuit for domestic hot water production is enabled. When a domestic hot water request is in progress, the icon flashes.
The P at the top of the domestic hot water icon indicates that the boiler pre-heating function is enabled; the P when flashing indicates that a pre-
heating request is in progress.
When the "central heating programming timing" function is enabled this icon indicates that the system heating (main zone) is in AUTOMATIC mode
(the management of the heating requests follows what has been set with the timer).
If the heating function is not enabled during the current time frame, the icon will be crossed out.
When the "central heating programming timing" function is enabled this icon indicates that the system heating (main zone) is in MANUAL mode (the
management of the heating requests does not follow what has been set with the programming timing, but it is always active).
OFF
This icon indicates that the system (main zone) has been set to off (not active).
This icon indicates that the system is detecting the presence of a flame.
This icon indicates the presence of an anomaly, and is always flashing.
REC10
Boiler control panel
Keys area
ENTER = confirm
BACK= Return to the previous page / cancel selection
Return to the main screen (press > 2 sec.)
+ =
Allows you to choose between the options: SYSTEM, STATUS, SET, INFO, MENU and to navigate
through the sub-menus scrolling upwards
- =
Allows you to choose between the options: SYSTEM, STATUS, SET, INFO, MENU and to navigate
through the sub-menus scrolling downwards
4 CONTROL PANEL (REC10)
The REC10 remote control has the function of a machine interface,
displaying the system settings and providing access to the
parameters.
The middle of the main screen displays the temperature of the
domestic hot water delivery (if there is a storage cylinder with
probe - optional) unless there is a heat request in heating mode, in
this case the delivery temperature of the boiler is displayed.
The value expressed in bar refers to the system's water pressure.
The top of the screen shows the information regarding the current
date and time, as well as the outdoor temperature, if available.
On the left and right sides are displayed the icons indicating the
status of the system, their meaning is the following:
The display of the REC10 control panel is equipped with the new “Color
Bar” that rapidly informs the user about the boiler operation.
The operating states and the alarms are grouped by 4 colours:
- GREEN: normal operation, the system is serving domestic hot water/
heating requests or else automatic functions like, for example, anti-
legionella, antifreeze, fl ue cleaning, etc.. Scrolling text describes the
function active in that moment
- YELLOW: presence of faults that could be resolved by the user that allow
the product to operate even partially. An error triangle on the display
gives access to details about the fault like, for example, “call for service”,
domestic hot water probe fault, etc...
- RED: presence of lockout faults that require the intervention of the
Technical Assistance Centre. An error triangle on the display gives
access to details about the fault like, for example, “stop for service”,
lockout, etc...
- GREY: system is ready to meet any requests or functions, no fault
detected.
If several conditions are present at the same time, the signal on the main
screen corresponds to the highest priority, in the following ascending order:
Grey, Green, Yellow and Red.
Pressing the “UP” and “DOWN” keys it is possible to select from among
the following options:
•
SYSTEM:
a scrolling message on the display can indicate the temperature
of the domestic hot water probe rather than the flow sensor of the boiler
•
STATUS (when the SYSTEM screen is selected):
to set the status of
the boiler (OFF, SUMMER or WINTER) and, when managed by the room
thermostat, the operating mode of the main area in heating mode (ON or
OFF) if the programming timing is disabled, AUTO according to hourly
programming, MANUAL or OFF if programming timing is enabled)
•
SET:
to establish the heating or hot water setpoint value or for activating
pre-heating
•
INFO:
to display the value of the system variables
•
MENU:
to access the system's configuration menus
The configuration MENU is organised with a multi-level tree structure. With
the “
ENTER
” key you can access the selected sub-menu, with the “
UP
”
and “
DOWN
” keys it is possible to navigate the sub-menus, while with the
“
BACK
” key you return to the previous level.
An access level has been fixed for each sub-menu: USER level always
available; TECHNICAL level password protected.
Below is a summary of the MENU tree structure of the REC10.
b
Some of the information might not be available on the REC10
depending on the access level, the status of the machine or the
system confi guration.
REC10
1.3
bar
42
°C
MENU
STATE
SET
INFO
PLANT
HOT WATER TEMPERATURE
FRI
18/05/2013
12:17
Info
CONFIRM
CANCEL button
GO BACK
DOWN key
UP key