The vent cycle can be interrupted by removing the cap
from the control panel and pressing the combustion
analysis button SW1 or in the following way:
-
select TECHNICAL
AIR PURGING CYCLE
STOP FUNCTION
INSTALLER
WEATHER COMPENSATION
RANGE RATED
CALIBRATION
AIR PURGING CYCLE
COMBUSTION ANALYSIS
TECHNICAL
STOP FUNCTION
FUNCTION DISABLED
FUNCTION ENABLED
INSTALLER
AIR PURGING CYCLE
The REC10CH will briefly display a wait message after which
you will automatically be taken to the main screen. The vent
cycle can also be interrupted, if the boiler is not set to OFF, by
a domestic hot water request.
30
°C
.3
MENU
STATE
SET
INFO
HOT WATER TEMPERATURE
FRI
1.3
bar
09/04/2021
12:17
PLANT
SUMMER (only if a water tank is connected):
select
STATE
BOILER
HOT WATER ONLY (SUMMER) to
activate the traditional function of only domestic hot water. The
REC10 normally displays the temperature of the domestic hot
water stocked in the water tank (only in case of water tank
with probe).
In case of water tank with thermostat or domestic hot water
request in progress, the delivery boiler temperature is
displayed.
OFF
HOT WATER ONLY
HEATING AND HOT WATER
BOILER
WINTER
/ :
select STATE
BOILER
HEATING
AND HOT WATER (WINTER): the operating mode of the
appliance is set to provide both heating and hot water.
NOTE:
the main zone also needs to be set to ON (embedded
clock disabled) or AUTO/MANUAL (embedded clock enabled)
in order for the appliance to provide heating.
The UI will display the flow outlet temperature is displayed.
OFF
HOT WATER ONLY
HEATING AND HOT WATER
BOILER
6.4 ADJUSTING THE HEATING WATER
TEMPERATURE WITHOUT AN
OUTDOOR TEMPERATURE SENSOR
CONNECTED
When there is no outdoor temperature sensor, the boiler
operates at a fixed-point, the HEATING setpoint in this case
can be set selecting SET on the main screen of the REC10
and selecting the desired value within the range [40°C -
80.5°C] for high temperature systems or [20°C - 45 °C] for low
temperature systems (default is high temperature).
DHW
SET
HEATING
6.5 ADJUSTING THE HEATING WATER
TEMPERATURE WITH AN OUTDOOR
TEMPERATURE SENSOR CONNECTED
When an outdoor temperature sensor is installed, the outlet
temperature is automatically selected by the system, which
quickly adjusts the ambient temperature according to the
variations in the outdoor temperature. If you want to change
the temperature, raising it or lowering it with respect to that
automatically calculated by the electronic board, it is possible
to change the HEATING setpoint by selecting SET on the
main screen of the REC10 and selecting within the range
(-5 - +5) the desired comfort level (see “6.2.5 Setting the
thermoregulation”).
Note:
when there is an outdoor temperature sensor connected
it is still possible to have the boiler operate at a fixed point
setting the values of MIN SP HEAT and MAX SP HEAT at the
desired HEATING setpoint.
6.6 ADJUSTING THE DOMESTIC HOT
WATER TEMPERATURE
CASE A:
only heating with no external water tank connected
- adjustment not applicable.
CASE B:
only heating with an external water tank managed
by a thermostat - adjustment not applicable.
CASE C:
only heating with an external water tank managed
by a probe.
To set the domestic hot water temperature (bath, shower, kitchen,
etc.):
SET
DHW
to choose the desired value between the
range [37,5°C ÷ 60°C].
SET
HEATING
DHW
6.7 ADDING DEVICES
-
Select
TECHNICAL
ADD WATER TANK
Then complete the configuration of the water tank referring
to the specific section
(section “6.15 Water tank configura-
tion”).
b
After adding the water tank, DHW is displayed on the
“Programme” page. This function allows the domestic
hot water programming timing to be carried out
.
6.8 BOILER START-UP
In order to initiate a heating request, it is essential that any time
or temperature control is set to an ON period and at a higher
than current ambient temperature respectively. The boiler will
be in standby until the burner switches on following a heat
request. The display shows “ ” to indicate the presence of
a flame
.