6
MAIN ZONE
Select
STATE
MAIN ZONE
to set the main zone’s status,
by choosing one of the following options:
- if the embedded time clock is disabled (default):
- ZONE ON: boiler responds to heating request
- ZONE OFF: boiler does not respond to any request for
heating
- if the embedded time clock has been enabled:
- AUTO/MANUAL/HEAT OFF.
ZONE ON
MAIN
ZONE OFF
AUTO
MANUAL
MAIN
HEAT OFF
Once the selection has been validated, the display returns to
the
STATE
screen.
ZONE ON:
if
ZONE ON
is selected, the zone heating requests
are met.
AUTO:
if
AUTO
is selected, the zone heating requests will be
managed based on the scheduled programme.
MANUAL
: if
MANUAL
is selected, the zone requests will be
managed based on the selection set by the user.
HEAT OFF:
If
HEAT OFF
is selected, the zone heating
requests will be ignored.
NOTE:
to deactivate the zone in SUMMER or in WINTER, you
must select the required season (SUMMER or WINTER in the
BOILER menu) and set the zone concerned to OFF.
HEAT PUMP (if present)
By selecting
HEAT PUMP
it is possible to enable the NIGHT
REDUCTION. This parameter is used to reduce the noise of
the heat pump by limiting the maximum operating frequency
of the compressor in the time band set by the parameters
NIGHT MODE START TIME and NIGHT MODE STOP TIME.
NIGHT MODE START TIME (if NIGHT REDUCTION is active)
This parameter is used to set the start time of the heat pump
compressor frequency limitation band when the night reduc-
tion function is enabled. Range 00:00 - 23:30/Default 22:00.
NIGHT MODE STOP TIME (if NIGHT REDUCTION is active)
This parameter is used to set the end time of the heat pump
compressor frequency limitation band when the night reduc-
tion function is enabled. Range 00:00 - 23:30.
ENABLE NIGHT REDUCT
HEAT PUMP
DISABLE NIGHT REDUCT
NIGHT MODE START TIME
HEAT PUMP
NIGHT MODE STOP TIME
2.7 SET
With this function it is possible to configure the setpoints.
Select
SET
HEATING
or
DHW
or
COOLING
setpoints.
HEATING
COOLING
SET
DHW
HEATING
The user can change the heating setpoint by pressing the
“up”
and
“down”
keys.
When an outdoor temperature sensor is installed, the outlet
setpoint temperature is automatically adjusted by the system,
in order to maintain the ambient temperature according to any
variations in the outdoor temperature. If you want to adjust
the outlet temperature, raising it or lowering it with respect
to that automatically calculated by the boiler, it is possible to
change the HEATING setpoint selecting the desired comfort
level within the range (-5 ÷ +5).
The user is then asked to confirm the setpoint setting: select
CONFIRM
or
CANCEL
and confirm.
Once the selection is confirmed, the display returns to the
SET
screen.If the selection is cancelled or the
“back”
key is
pressed you return to the previous
SET
screen.
SET
HEATING
78,0
°C
SET
THE PARAMETER
WILL BE CHANGED
CONFIRM
CANCEL
CONFIRM OR DELETE
SELECTION
HOT WATER
With heating only boiler connected to a domestic hot water
tank, the parameter refers to the temperature of the domestic
water stored in the water tank.
Press the “up” and “down” keys to modify the domestic water
set point delivered by the boiler and then confirm with OK.
The user is then asked to confirm the setpoint setting: select
CONFIRM or CANCEL and confirm. Once the selection
is confirmed, the display returns to the SET screen. If the
selection is cancelled or the “BACK” key is pressed you return
to the previous SET screen.
CONFIRM OR DELETE SELECTION
CONFIRM
CANCEL
THE PARAMETER WILL BE
CHANGED
58,0
°C
HOT WATER
SET
COOLING (AVAILABLE IF HEAT PUMP
ENABLED FOR COOLING IS INSTALLED)
Press the “up” and “down” keys to change the cooling setpoint
and then confirm
. If the thermoregulation in cooling is activated,
the flow temperature value is automatically chosen by the
system, which rapidly adjusts the room temperature according
to the variations in the external temperature. If you want to
change the temperature value, increasing or decreasing it
compared to that automatically calculated by the electronic
board, you can change the COOLING setpoint by choosing the
desired comfort level (-5 ÷ +5) within the range. Then you are
asked to confirm the setpoint setting: select ENTER or BACK
using “up” and “down”, validate the choice by pressing OK.
Confirming the selection returns the display to the previous
SET screen. Cancelling the selection or pressing the BACK
button returns the display to the SET screen.
NOTE: this parameter is available when in the system a heat
pump enabled for room cooling is installed.
20,0
COOLING
°C
2.8 INFO
The
INFO
function can be used to display a series of data
regarding the system.
ATTENTION
- The displayed data is for information only and
cannot be modified.
SCREED HEATER OPERATING HOURS
DELIVERY PROBE
RETURN PROBE
DOMESTIC HOT WATER PROBE
HIGH STORAGE TANK PROBE
LOW STORAGE TANK PROBE
SOLAR COLLECTOR
FLUE GAS PROBE
OUTDOOR TEMPERATURE SENSOR
EXT T FOR THERMOREG
FLOW METER / DHW SETPOINT OT+
FAN
DELIVERY ZONE 1
DELIVERY ZONE 2
FLUE GAS PROBE OPERATING
HOURS
MAIN ZONE SET-POINT
ZONE 1 SET-POINT
ZONE 2 SET-POINT
SYSTEM PRESSURE
HEAT PUMP DELIVERY
HEAT PUMP RETURN
HEAT PUMP EXT. TEMP.
TREFR LOW PRESSURE PIPE
TREFR HIGH PRESSURE PIPE
TREFR CONDENSER
TREFR HEAT EXCHANGER
HEAT PUMP OPERATING MODE
HEAT PUMP FREQUENCY
HEAT PUMP COMPRESSOR TIME
HEAT PUMP CIRCULATOR TIME
HEAT PUMP FLOW SWITCH
HEAT PUMP OUTPUT
HEAT PUMP SET-POINT
NEXT ANTI-LEGIONELLA