Note Before First Use
Rieber GmbH & Co. KG
35
The
keep-cold
temperature is adjustable
from +10 °C to
–7 °C
.
When the operating mode is changed from keep-cold to keep-warm the appliance starts immediately.
The
keep-warm
temperature is adjustable
up to +120 °C
.
When the operating mode is changed from keep-warm to keep-cold, the appliance starts when the
stainless steel plate has cooled down to around 40 °C.
If you wish to switch the appliance ON/OFF
➢
On the built-in unit K|POT
®
1/1 hybrid-SP-i built-in, always press the main switch/rocker switch.
▌
In the OFF position the unit is disconnected from the power.
➢
Press the ON/OFF button (5) to switch on.
▌
The illuminating control indicator (7) indicates the current operating mode. The
last setting for the set point temperature is activated.
▌
The display (6) shows the actual temperature on the GN 1/1 surface.
If you wish to know the programmed set point temperature
➢
Press the SET button (2).
▌
The display (6) shows the set point temperature.
▌
If the SET button is not pressed, the actual temperature appears again.
If you wish to change the set value for keeping warm or cold
➢
Press the program selector button for keep-cold operating mode (4) or the program selector button
for keep-warm operating mode (3).
▌
The selected operating mode is activated.
➢
Keep the
SET button
(2) pressed and change the setting with the
+
– button
(1).
▌
The display (6) shows the set point temperature.
➢
Release the SET button (2).
➢
If the SET button is not pressed, the actual temperature appears.
If you wish to change the operating mode
➢
Press the program selector button for keep-cold operating mode (4) or the program selector button
for keep-warm operating mode (3).
▌
After around 1 minute the selected operating mode starts with the set point
temperature last set.
▌
The GN 1/1 surface starts cooling, when the temperature on the surface falls
below +40 °C.