Purpose
14
Rieber GmbH & Co. KG
4.2
Prevent any predictable misuse and abuse
# Prevent any potential misuse in advance, general
•
Never operate the appliance unsupervised.
•
Do not operate the appliance outdoors. Keep the appliance away from moisture.
•
Do not operate the appliance in dimly lit places.
•
Do not lean against or sit on the appliance.
•
Keep any combustible or explosive fluids away from heatable appliances. Otherwise a fire
or explosion may occur.
•
Never operate the appliance with an empty cooking container.
•
After 3 hours the total permissible regenerating and keep-warm time according to the health
requirements is reached. Comply with the HACCP requirements.
•
Do not use to heat up a room.
•
The installation of the built-in unit may only be performed by specialists. Electrical work
may only be performed by a trained and experienced
qualified electrician
.
4.3
Special intended use for appliances
with a Ceran
®
glass surface
# Prevent foreseeable misuse
➢
Danger of electric shock. If the Ceran
®
glass surface is damaged, if there is a crack in the glass for
example, disconnect the appliance from the mains supply immediately. If possible avoid
electrically conductive materials in the immediate vicinity, for example metal splash guards.
➢
When using an appliance with a Ceran
®
glass surface, never place a hot pot on the cold Ceran
®
glass surface or a cold pot on the “hot” Ceran
®
glass surface, otherwise the Ceran
®
glass surface
could crack due to thermal stresses.
➢
Even a seemingly light object such as a salt cellar can cause cracks or breaks in the Ceran
®
glass
surface in the worst case scenario. Prevent objects from falling onto the Ceran
®
glass surface.
➢
Do not place aluminium foil or plastic containers on the Ceran
®
glass surface, as this could cause
damage.
4.4
Special intended use for appliances with an induction hob
# Prevent foreseeable misuse
➢
Persons with a pacemaker may experience interference or influence when handling an induction
appliance due to electromagnetic radiation. We recommend that the operator takes the following
precautions: Keep persons with a pacemaker away from the appliance initially. Identify this
workplace where necessary. Have the doctor clarify the actual situation and individual compatibility
where necessary.
➢
The induction generator could switch off or be damaged. Only use the appliance with induction-
compatible and approved cookware. Semi-inductive cookware will result in a decreased cooking
performance; the efficiency will be substantially reduced.