Note Before First Use
32
Rieber GmbH & Co. KG
7.6.6
Automatic preheating
The purpose
of the automatic preheating is to trigger the following heat setting.
•
This function is activated by
fully turning
the power regulator
to the left
with a
holding
time
of
at least 2 seconds
.
A heat setting must be selected
on the power regulator
within 10 seconds
,
the so-called continuous
cooking setting
.
•
If heat settings 0, 1, 2, 9 are selected or if the power regulator is turned all the way to the
left/right, then the automatic preheating is not activated.
7.6.7
Boost function
•
With the boost function you can set a time limit,
a maximum of 10 minutes
, for operating a
cooking zone at maximum power.
•
If both hobs are selected in the booster function, then the last selection takes priority. The
other cooking zone is automatically reduced to half power. The maximum possible power of
the appliance is constant.
➢
To activate this function,
turn the power regulator to setting 8, then to setting 9 as far as the
stop.
Then set the power regulator to setting 8.
➢
To deactivate the function,
turn the power regulator anticlockwise to a setting below 8.
▌
After 10 minutes the function switches off automatically.
7.6.8
Bridging function
•
On the induction hob, two defined cooking zones can be "bridged". These can be controlled
as if they were "one" cooking zone.
•
The left cooking zone is the main cooking zone. The right cooking zone is the additional
cooking zone.
•
The power regulator
of
both cooking zones
must
be turned all the way to the right
simultaneously
.
Minimum holding time 2 seconds
. The
power regulator
of the
additional cooking zone
must then be set to
heat setting 9
.
7.6.9
Automatic shut-off (operating time limitation OTL)
•
Depending on the heat setting selected for each cooking zone, a maximum permissible
operating time (without any changes in heat setting) is defined.
•
If this maximum time limit is exceeded, the respective cooking zone is switched off.
•
The cooking zone can only be restarted after resetting ("zero setting") the power regulator.
•
The time remaining until automatic shut-off is reset to the initial value after each new
operation of the cooking zone.
Heat setting:
OTL
[minutes]:
Heat setting:
OTL
[minutes]:
1
120
6
90
2
360
7
90
3
360
8
90
4
300
9
Boost
5
300