2 - 4
32DPF702.A
a. Refer
to
Figure 2-4
. Slide flutter valve onto holder.
b. Refer
to
Figure 2-4
. Place hose clamp over flutter valve and tighten to secure valve in place.
B. ELECTRICAL
INSTALLATION
1. GENERAL SAFETY PRECAUTIONS
WARNING!
MAKE SURE THAT THE POWER SOURCE IS DISCONNECTED WHEN
ROUTING WIRES. THERE IS DANGER OF ELECTRIC SHOCK IF THE
POWER SOURCE IS NOT DISCONNECTED.
♦
Avoid interference with train parts and/or avoid touching the protuberance.
♦
Make sure wires or harnesses are protected and secured with cable ties every 18 inches (45 cm).
♦
Use caution to avoid tearing or other damage to the insulation on the wires.
2. MAIN
WIRING
a. Refer
to
Figure 2-5
. Locate motor cable and sensor cable inside ramp enclosure next to the motor.
FIGURE 2-5: MOTOR AND SENSOR CABLES
b. Refer
to
Figure 2-6
. Run wire bundle into motor area through conduit connector near flutter valve.
FIGURE 2-6: PASSING WIRE BUNDLE THROUGH HOLE