32DPF702.A
2 - 3
REAR END
MOUNTING HARDWARE
MID-SECTION
MOUNTING HARDWARE
FRONT MOUNTING
HARDWARE
RAISED
HINGED
FLOOR
ROD
FIGURE 2-3: INSTALLING MOUNTING FASTENERS
l. Tighten mounting bolts in an alternating pattern in small increments, stepping up to the maximum value of
27 to 33Nm manually using a manual torque wrench. Do not tighten each bolt all at once. A pneumatic or
any automatic device is not recommended.
m. Perform electrical installation before continuing with the following step. For electrical installation, please
refer to the Electrical Installation section of this chapter.
n. Disengage rod under hinged floor and secure underneath with clip. Close hinged floor.
o. Rotate timing belt in opposite direction until the ramp is fully stowed.
p. Install access panel.
q. Install cover strips and hardware.
3. 3. FLUTTER DRAIN VALVE INSTALLATION
The purpose of the flutter valve is to allow fluid to drain out of enclosure, while keeping debris from entering. Flut-
ter valve and hose clamp are provided with ramp in kit #39023.
FLUTTER VALVE
HOSE CLAMP
FIGURE 2-4: FLUTTER VALVE INSTALLATION