2 - 18
32DPF702.A
4. CRIMPED - 6mm
2
WIRE
a. Refer
to
Figure 2-30
. Strip approximately 9.0
∼
10.0mm of insulation by using the appropriate wire strip-
ping tool for a 6mm
2
wire.
b. To easily insert the bare conductor into the female terminal, straighten the tip of the bare conductor.
FIGURE 2-30
c. Refer
to
Figure 2-31
. Insert the female terminal 42815-0031 and the stripped wire into the crimping tool
63811-1500 and crimp them accordingly.
FIGURE 2-31
d. Refer
to
Figure 2-32
. Insert the crimped wire into the receptacle housing 42816-0212.
FIGURE 2-32
e. Refer
to
Figure 2-33
. Insert the crimped wire into the receptacle housing until the terminal’s latch is en-
gaged. Remove the tab that is attached to the top of the housing.
FIGURE 2-33