TECHNICAL SPECIFICA
TION
• 1.09.409E
• 3.10.2012
• Typ A3550 E
© VALLOX
VALLOX 132 E R
Vallox
E
132
Electrical connection
230 V, 50 Hz
Class of protection
IP 34
Fans
Extract air
210 W 0.91 A (AC) 120 dm
3
/s (120 Pa)
Supply air
210 W, 0.91 A (AC)110 dm
3
/s (100 Pa)
Heat recovery
Cross-flow cell, n > 60%
Filters
Supply air
G4 and F7
Extract air
G4
Weight
71 kg
Power adjustment
Separate four-step speed selector
or PTXP/i132 cooker hood
Options 132 E/132 E VKL
Filter guard (supply and/or extract air)
Insulated attic floor penetration plate
Ceiling mounting plate Vallox 132 E
VKL expansion tank + stand
VKL heat exchanger pipe
for Vallox 132 VKL
Fireplace switch with 0-120 min.
timer, surface mounting
Fireplace switch with 0-120 min.
timer, flush mounting
Silencer unit
Options VALLOX 132 E
2.7 kW, 12.0 A
Preheating unit
Electric 1200 W, 5.2 A
Post-heating unit Electric 1200 W, 5.2 A
Options VALLOX 132 E VKL
1.55 kW, 6.7 A
Preheating unit
Electric 1200 W, 5.2 A
Post-heating unit VKL water radiator
Speed selection switch
• Cross-flow heat recovery cell
(
>60%)
• Alternating current fans
• 4-step transformer adjustment
• Fireplace/booster function (optional)
• Manual heat recovery cell bypass
during summer
• Fireplace switch function (option)
• Antifrost
• Maintenance reminder
• Good outdoor air filtering (F7)
• Wide selection of radiator options
• Silencer unit (option)