Service Call Conditions
M052/M053/M054 6-12
SM
SC6xx: Device Communication
610
D
Mechanical counter error: K
- -
This SC is only for NA models.
The machine detects the mechanical counter error when SP5987-001 is
set to "1".
Disconnected mechanical counter
Defective mechanical counter
Defective
BICU
620
D
Communication error between BICU and ADF
A break occurred in the connection between the BICU and ADF
ADF
disconnected
ADF
defective
BICU harness connection loose, broken
BICU
defective
External
noise
621 D
Communication
timeout
between BICU and finisher
A break (LOW) signal was received from the finisher.
Finisher serial cable connection loose, broken
BICU
defective
Finisher main board defective
External
noise
Summary of Contents for M052
Page 1: ...M052 M053 M054 SERVICE MANUAL ...
Page 15: ......
Page 20: ...PRODUCT INFORMATION REVISION HISTORY Page Date Added Updated New None ...
Page 21: ......
Page 31: ......
Page 76: ......
Page 77: ...PREVENTIVE MAINTENANCE REVISION HISTORY Page Date Added Updated New None ...
Page 78: ......
Page 82: ......
Page 210: ...1 Bin Tray Unit M052 M053 M054 4 128 SM 10 Remove two screws A ...
Page 214: ......
Page 216: ......
Page 426: ......
Page 466: ......
Page 467: ...ENERGY SAVING REVISION HISTORY Page Date Added Updated New None ...
Page 468: ......
Page 474: ...M052 M053 M054 SERVICE MANUAL APPENDICES ...
Page 475: ......
Page 477: ......
Page 479: ......
Page 495: ......
Page 496: ...APPENDIX PREVENTIVE MAINTENANCE TABLES REVISION HISTORY Page Date Added Updated New None ...
Page 497: ......
Page 501: ...M381 FAX OPTION TYPE SP5200 REVISION HISTORY Page Date Added Updated New None ...
Page 502: ......
Page 506: ......
Page 649: ......
Page 651: ......
Page 653: ......