Bit Switches
SM Appendix
5-9
D127/D128
A
ppe
n
dix
:
Fa
x
T
rou
ble
-
S
h
oo
ting
Gu
ide
e.g. 0000 (1) // 32 (2) V34 (3) // 288 (4) // 264 (5) // L0100 (6) 03 (7) 04 (8)
(1): EQM value (Line quality data). A larger number means more errors.
(2): Symbol rate (V.34 only)
(3): Final modem type used
(4): Starting data rate (for example, 288 means 28.8 kbps)
(5): Final data rate
(6): Rx level (refer to the note after this table for how to read the rx level)
(7): Total number of error lines that occurred during non-ECM reception.
(8): Total number of burst error lines that occurred during non-ECM reception.
EQM and rx level are fixed at “FFFF” in tx mode.
The seventh and eighth numbers are fixed at “00” for transmission records
and ECM reception records.
Rx level calculation
Example: 0000 // 32 V34 // 288/264 // L 01 00 03 04
The four-digit hexadecimal value (N) after “L” indicates the rx level.
The high byte is given first, followed by the low byte. Divide the decimal value of N
by -16 to get the rx level.
In the above example, the decimal value of N (= 0100 [H]) is 256.
So, the actual rx level is 256/-16 = -16 dB
3
Not used
Do not change this setting.
4
Line error mark print
0: OFF, 1: ON (print)
When "1" is selected, a line error mark is printed
on the printout if a line error occurs during
reception.
5
G3/G4 communication
parameter display
0: Disabled
1: Enabled
This is a fault-finding aid. The LCD shows the key
parameters (see below). This is normally disabled
because it cancels the CSI display for the user.
Be sure to reset this bit to 0 after testing.
6
Protocol dump list output after
each communication
0: Off
1: On
This is only used for communication
troubleshooting. It shows the content of the
transmitted facsimile protocol signals. Always
reset this bit to 0 after finishing testing.
If system switch 09 bit 6 is at “1”, the list is only
printed if there was an error during the
communication.
Summary of Contents for LANIER MP 301SP
Page 1: ...D127 D128 SERVICE MANUAL ...
Page 12: ......
Page 17: ...PRODUCT INFORMATION REVISION HISTORY Page Date Added Updated New None ...
Page 18: ......
Page 31: ...INSTALLATION REVISION HISTORY Page Date Added Updated New None ...
Page 32: ......
Page 76: ......
Page 77: ...PREVENTIVE MAINTENANCE REVISION HISTORY Page Date Added Updated New None ...
Page 78: ......
Page 81: ...REPLACEMENT AND ADJUSTMENT REVISION HISTORY Page Date Added Updated New None ...
Page 82: ......
Page 136: ...ARDF D127 D128 4 54 SM 5 Holder A x 1 6 Hinge A x 3 7 Bracket A x 2 ...
Page 146: ......
Page 147: ...SYSTEM MAINTENANCE REFERENCE REVISION HISTORY Page Date Added Updated New None ...
Page 148: ......
Page 164: ......
Page 165: ...TROUBLESHOOTING REVISION HISTORY Page Date Added Updated New None ...
Page 166: ......
Page 215: ...ENERGY SAVING REVISION HISTORY Page Date Added Updated New None ...
Page 216: ......
Page 225: ...D127 D128 SERVICE MANUAL APPENDICES ...
Page 226: ......
Page 230: ......
Page 231: ...APPENDIX SPECIFICATIONS REVISION HISTORY Page Date Added Updated New None ...
Page 232: ......
Page 248: ......
Page 249: ...APPENDIX PREVENTIVE MAINTENANCE TABLES REVISION HISTORY Page Date Added Updated New None ...
Page 250: ......
Page 254: ......
Page 256: ......
Page 417: ...APPENDIX FAX TROUBLESHOOTING GUIDE REVISION HISTORY Page Date Added Updated New None ...
Page 418: ......
Page 450: ......
Page 451: ...APPENDIX FAX SERVICE PROGRAM REVISION HISTORY Page Date Added Updated New None ...
Page 452: ......
Page 544: ...D661 PAPER FEED UNIT PB1040 REVISION HISTORY Page Date Added Updated New None ...
Page 545: ......
Page 547: ......