Blown Fuse Conditions
• Use a correct rating fuse for the fuse replacement. Never use a wrong rating fuse. If do so, the machine
may be damaged.
Fuse
Rating
Symptom when turning on the main switch
120 V
220 - 240 V
Power Supply Board
FU1
15 A/125 V
8A/250V
Machine does not start.
FU2
5.0 A/125 V
3.15 A/250 V
Machine does not start.
FU3
4 A/125 V
4 A/250 V
Machine does not start.
FU4
5 A/125 V
5 A/250 V
Machine does not start.
FU5
6.3V/125V
6.3 A/250V
"Please Wait" is displayed, but machine
does not start or SC is issued on the LCD.
LEDs
No LEDs are used for this model.