2. Appendix: Troubleshooting Guide
Service Call Conditions
Summary
There are 2 levels of service call conditions.
Level
Definition
Reset Procedure
A
Only a service representative can reset this
SC. This will prevent damage to the
machine.
You cannot use the machine.
Enter engine SP mode 5810 and press "#".
When 'execute' is displayed, press "#"
again. Then press 'Escape'. Then turn the
main power off/on.
B
The SC can be reset by turning the
operation switch off and on, if the SC was
caused by a sensor error.
Set the main power off and on.
C
SCs that are not shown on the operation
panel. They are internally logged.
Logging only
• If the problem is with electrical circuit boards, disconnect the connectors first. Then reconnect the
connectors before you replace the PCBs.
• If the problem is with a motor lock, first examine the mechanical load. Then replace motors or sensors.
SC Code Descriptions
Engine SC
Code No.
Symptom
Possible Cause
202
B
Polygon motor error
11
2
Summary of Contents for Kr-P2
Page 1: ...Model Kr P2 Machine Code M047 Field Service Manual 15 December 2009...
Page 2: ......
Page 11: ...1 Product Information Specifications See Appendices for the General Specifications 9 1...
Page 16: ...1 Product Information 14 1...
Page 22: ...2 Installation 20 2...
Page 26: ...3 Preventive Maintenance 24 3...
Page 44: ...3 Toner end sensor A 4 hooks x 1 4 Replacement and Adjustment 42 4...
Page 54: ...2 Hot roller strippers A 1 spring each B 4 Replacement and Adjustment 52 4...
Page 65: ...3 Sensor box A hooks 4 Fusing exit sensor A hooks x 1 Paper Exit 63 4...
Page 69: ...3 Harness guide A Rivet screw x 1 4 Clutch cover A x 1 Electrical Components 67 4...
Page 78: ...4 Replacement and Adjustment 76 4...
Page 97: ...Model Kr P2 Machine Code M047 Appendices 15 December 2009...
Page 98: ......
Page 100: ...2...
Page 108: ...1 Appendix Specifications 10 1...
Page 200: ...3 Appendix SP Mode Tables 102 3...