2.12 SC CODE E-12: CHARGE CORONA CLEANER MOTOR
ABNORMAL
-Definition-
1. The over current of the charge corona wire drive motor is not detected
continually for 1.5 seconds within 3 minutes after main switch is turned on.
2. The over current of the charge corona wire drive motor is not detected
twice within 3 minutes after the charge corona motor is energized.
<Point to check>
Charge cleaner motor
Mechanical interference of the charge cleaner motor
2.13 SC CODE E-13: TOTAL COUNTER ABNORMAL
-Definition-
Total counter does not operate.
<Point to check>
Total counter and its connection.
2.14 SC CODE E-14: ZERO CROSS SIGNAL DETECTION
ABNORMAL
-Definition-
The zero cross signal is not detected within 0.5 second after the main switch
is turned on.
<Point to check>
Main board
AC Drive board
SERVICE CALL CONDITION
25 July 1994
6-12