3.5 MANUAL ID CONTROL VS ADS
Manual ID Level
Light Sensor
Output [V]
Manual ID Level
Light Sensor
Output [V]
1
1.275
14
1.882
2
1.275
15
1.922
3
1.275
16
2.020
4
1.294
17
2.118
5
1.294
18
2.216
6
1.314
19
2.314
7
1.333
20
2.412
8
1.373
21
2.529
9
1.412
22
2.627
10
1.510
23
2.725
11
1.627
24
2.824
12
1.745
25
2.922
13
1.843
26
3.118
3.5.1 Manual ID Control
When in manual image density mode, the user can select one of 26 manual
ID levels. For each level, the intensity of the light output by the exposure
lamp (as measured by the light sensor) is fixed. This is shown in the above
table. The development roller bias also varies. (See the section on
development bias.)