3.2 INPUT/OUTPUT CHECK MODE
The input check mode allows you to check the current status of electrical
components (such as sensors, switches, etc.) from the operation panel.
The output check mode allows you to turn the individual electrical
components (such as motors, solenoids, etc.) ON/OFF from the operation
panel.
3.2.1 INPUT/OUTPUT CHECK MODE ACCESS PROCEDURE
How to access the output check mode
Press the following keys in sequence.
→
9
→
9
→
=
→
=
The second time that the"Clear Stop" key is pressed, hold it down for more
than 3 seconds (until the
and
indicators blink).
How to leave the input/output check mode
Press the following keys in sequence.
→
→
or turn off the main switch.
NOTE: Each of the above procedures must be finished within 20
seconds.
How to select the program number
The program number can be selected by pressing the "+" and "–" keys.
To select an input check mode, press the "–" key.
To select an output check mode, press the "+" key.
The selected number is displayed on the lead edge erase indicator (the two
digit indicator beside the
mark).
To select the program number quickly, hold down the "+" or "–" key.
S
e
rvice
Tab
les
25 July 1996