IP-Fax Switch 01
No.
FUNCTION
COMMENTS
Select IP FAX Delay Level
Bit3 Bit2 Bit1 Bit0 Setting
0 0 0 0 Level
0
0 0 0 1
Level
1
0 0 1 0
Level
2
0 0 1 1
Level
3
0-3
Raise the level by selecting a higher setting
if too many transmission errors are occurring
on the network.
If TCP/UDP is enabled on the network, raise
this setting on the T.30 machine. Increasing
the delay time allows the recovery of more
lost packets.
If only UDP is enabled, increase the number
of redundant packets.
Level 1 to 2: 3 Redundant packets
Level 3: 4 Redundant packets
4-7
IP Fax preamble wait time setting
Selects the preamble wait time.
[00 to 0f]
There are 16 values in this 4-bit binary
switch combination.
Waiting time: set value level x 100 ms
Max: 0f (1500 ms) Min: 00 (No wait time)
The default is "0000" (00H).
IP Fax Switch 02 [SP No. 1-111-003]
No.
FUNCTION
COMMENTS
0
IP Fax bit signal reverse setting
0: Maker code setting
1: Internal bit switch setting
When "0" is selected, the bit signal reverse
method is decided by the maker code.
When "1" is selected, the bit signal reverse
method is decided by the internal bit switch.
(When communicating between IP Fax
devices, LSB first is selected.)
Summary of Contents for D067
Page 1: ...D067 D068 D069 D072 SERVICE MANUAL 004356MIU ...
Page 2: ......
Page 3: ...D067 D068 D069 D072 SERVICE MANUAL ...
Page 4: ......
Page 5: ...D067 D068 D069 D072 SERVICE MANUAL 004356MIU ...
Page 6: ......
Page 8: ......
Page 10: ......
Page 12: ......
Page 21: ......
Page 23: ......
Page 28: ......
Page 29: ...PRODUCT INFORMATION ...
Page 30: ......
Page 46: ...D067 D068 D069 D072 16 SM INSTALLATION ...
Page 88: ...Printer Scanner Unit D067 D068 D069 D072 2 42 SM ...
Page 110: ...PREVENTIVE MAINTENANCE ...
Page 113: ...REPLACEMENT ADJUSTMENT ...
Page 114: ......
Page 183: ......
Page 184: ...TROUBLESHOOTING ...
Page 191: ......
Page 222: ...DO67 D068 D069 D072 SERVICE MANUAL APPENDICES ...
Page 223: ......
Page 228: ...APPENDIX SPECIFICATIONS ...
Page 229: ......
Page 248: ...APPENDIX PREVENTIVE MAINTENANCE TABLES ...
Page 249: ......
Page 253: ......
Page 254: ...APPENDIX SERVICE CALL CONDITIONS ...
Page 255: ......
Page 302: ...APPENDIX ELECTRICAL COMPONENT DEFECTS ...
Page 303: ......
Page 307: ......
Page 309: ......
Page 497: ......
Page 498: ...APPENDIX FAX TROUBLESHOOTING GUIDE ONLY FOR D068 D069 ...
Page 499: ......
Page 538: ...APPENDIX FAX SERVICE PROGRAM ONLY FOR D068 D069 ...
Page 539: ......
Page 645: ...PAPER TRAY UNIT B421 ...
Page 647: ......
Page 657: ...ARDF DF1000 B872 ...
Page 658: ......
Page 660: ......
Page 662: ......