北京锐志天宏科技股份有限公司
Beijing RichAuto S&T Co., Ltd
Forging ahead, create future together!
25
Delete File
:
Delete inner file that copy from U disk.
File Info
:
It can calculate the total time of processing file and processing range.
4.2.3
Machine Setup
The manufacturer
parameters which are under “Machine Setup” can be set by
machine producers according to their equipment types. Users are required to change the
machine parameters under the technician‟s guidance of the machine produce.
Menu Structure of Machine Setup
1) Pulse Equiv
Linear axis:
The number of pulses required to send from the system when machine
moves every 1mm. Unit: pulse / mm;
Rotating axis:
The number of pulses required to send from the system when machine
rotate every 1 degree. Unit: pulse / degree.
Calculation method please refer to PS1.1.2
Setting mode:
Enter “
Pulse Equiv
”, cursor is in the X axis pulse equivalent position,
Machine Setup
Pulse Equiv
Table Size
Home Setup
Spdl Confi
TS Setup
Motion Axis Set
Accel Setting
I/O Port Setting