1) The origin detection switch types do not match with the definition of the
corresponding voltage level. Modify the voltage level in the controller. (Normally open
type corresponds to a level defined the direction of the arrow down, normally closed
type corresponds to the level defined arrow up).
2) The origin detection switch is broken. Replace a new one.
3) The origin detection switch connects interface board not well. Refresh the cable to
confirm the wiring is correct.
4) Too much interference, resulting in the illusion of the detection switch has been
triggered. Recalibrated the whole circuit.
5) The interface board is broken. Depot Repair.
6) 50-pin data cable is broken. Replace the data cable.
Abnormally running when processing or the actual file is different from theoretical
file
1) The system program disorder.
2) Too much external interference lead the controller cannot work normally. Re-adjust
overall circuit. (The wires of weak current and strong current should be separately
binding, the inverter and other components should be separated connected each
GND of themselves).
3) There is something wrong while converting the file format and the program appears
illegal characters or system unrecognized codes. Recommended to use third party
simulation software to review the program paths.
Start automatic tool setting, the tool does not stop after touching C.A.D (Tool
sensor).
1) The cutter signal cable connects X5 maybe broken circuit.
2)
The "GND" signal port on the interface board hasn‟t been connected with spindle
housing or poor connection.
3)
Go to “MACHINE SETUP”-“Input Confi” to confirm if X5 is enabled.