北京锐志天宏科技股份有限公司
Beijing RichAuto S&T Co., Ltd
Forging ahead, create future together!
31
storage space. The backup file format is data.bak and config.bak.
Param Backup: To backup all of the parameters of the machine tool, default format is
data.bak.
Func Backup: To backup the function configuration of the machine tool, default format is
config.bak.
4) System Restore
Data Format
:
After data initial system parameters will restore to factory setting (Machine
size, pulse equivalent etc.)
Internal Format
:
Wipe the internal files, it will not remove the system parameters after
inner format.
Cache Initialize
:
The system needs wipe cache when it has been using for a long time or
after the system upgrading, it will ask to reboot after “Wipe Cache” operation.
Func Initial: Restore factory Settings for all functional configuration of the machine tool
(return to zero order, processing operation, etc.)
Func Restore: Restore the backup system parameters by choosing the
“config.bak”
file
from the U disk or internal storage area.
Param Restore: Restore the backup system parameters by choosing the
“data.bak”
file
from the U disk or internal storage area.
5) Trial Time
To be used to set the trail time of the controller, counting by day from the date of setting.
User should send the origin 20 digits to us, then get new 20 digits from us and enter them
into the controller, after that, the trail time will take effect.
6) Menu PW
Encrypt the system menu. User should contact the factory to reset it if wants to change the
settings in MENU.
7) System Upgrade
If we added new functions, we will offer upgrade file which extension name is
******.PKG
format (File name is
rz-xxxx
or
q13-xxxx
). User could update the system through U disk,
for more details please see PS1. System updating doesn‟t remove the controller original
parameters.
Upgrade package format sample:
.