北京锐志天宏科技股份有限公司
Beijing RichAuto S&T Co., Ltd
Forging ahead, create future together!
55
Rotation axis
pulse equivalent * 360°*mechanical transmission ratio
Appendiex 2. Common problems and
PS2.1 Solutions for screen display faults
After powered on the “Screen flicker or automatically restart”
1)
Switching mode power supply is insufficient. Check power supply if there are
problems, and change high-quality power supply to solve the problems.
2)
The local power grid unstable. Check local grid voltage stability or use the regulator
filter device.
3)
The power chip of the handle is ageing. This phenomenon also appears when the
handle is powered through the USB cable to the computer. Please return back the
handle to our company.
4)
Temporary solution. Using standard 5V mobile phone charger, supply power through
the USB cable to handle. Duplicate power supply for temporary emergency use.
Failed to set work piece origin during normal operation process
1)
It is under the mechanical coordinate system. Check if the main interface displays AX
AY AZ, AA, if yes, should press "
" + "
" switching to work coordinate
system. Then it can set work origin. Press "
" + "
" is for going to
mechanical coordinate system where cannot set work origin in there.