Configuration
21
3.2.3
Calibration Menu
See Section 4.0 on page 33 for calibration procedures.
Figure 3-6. Calibration Menu
CALIBR Menu
Parameter
Choices
Description
Level 2 submenus
WZERO
—
Display and edit the zero calibration A/D count value.
WVAL
—
Display and edit the test weight value.
WSPAN
—
Display and edit the span calibration A/D count value.
WLIN
PT->1 —
PT->5
Display and edit test weight and calibration values for up to five linearization points.
REZERO
—
Press Enter to remove an offset value from the zero and span calibrations.
Table 3-4. Calibration Menu Parameters
XXXXXXX
XXXXXXX
XXXXXXX
XXXXXXX
WZERO
*CALIB*
Display and edit
zero calibration
A/D count value
Display and edit
test weight value
WVAL
*CALIB*
Display and edit
span calibration
A/D count value
WSPAN
ALGOUT
DIGIN
SETPNTS
PROGRM
PFORMT
SERIAL
CALIBR
CONFIG
FORMAT
*
CALIB*
Press Enter to
remove offset from
zero and span
calibrations
REZERO
WLIN
PT–> 1
PT–> 2
PT–> 3
PT–> 4
PT–> 5
Same as PT-> 1
Display and edit
test weight value
*CALIB*
Display and edit
linearization point
A/D count value
VERS