Analog Output Menu
The ALGOUT menu is used only if the analog output option is installed. If the analog output option is installed,
configure all other indicator functions and calibrate the indicator before configuring the analog output. See
Section 10.7 on page 69 for analog output calibration procedures.
Figure 3-15. Analog Output Menu
3.2.10
Version Menu
The VERS menu is used to check the software version installed in the indicator. There are no parameters
associated with the Version menu: when selected, the indicator displays the installed software version number.
Figure 3-16. Version Menu
XXXXXXX
XXXXXXX
ALGOUT
DIG IN
SETPNTS
XXXXXXX
PROGRM
PFORMT
SERIAL
CALIBR
XXXXXXX
CONFIG
FORMAT
SOURCE
GROSS
0%
20%
OFFSET
ERRACT
FULLSC
HOLD
000000
number
MIN
10000
number
MAX
TWZERO
NET
TWSPAN
ZEROSC
XXXXXXX
VERS
ALG OUT Menu
Parameter
Choices
Description
Level 2 submenus
SOURCE1
GROSS
NET
Specifies the source tracked by the analog output.
OFFSET
0%
20%
Zero offset. Selects whether the analog output supplies voltage (0–10 V) or current (4–20 mA)
output. Select 0% for 0–10 V output; select 20% for 4–20 mA output.
ERRACT
FULLSC
HOLD
ZEROSC
Error action. Specifies how the analog output responds to system error conditions.
Possible values are:
FULLSC: Set to full value (10 V or 20 mA)
HOLD: Hold current value
ZEROSC: Set to zero value (0 V or 4 mA)
MIN
000000
number
Specifies the minimum weight value tracked by the analog output. Specify a value in the range
0–9999800.
MAX
010000
number
Specifies the maximum weight value tracked by the analog output. Specify a value in the range
0–9999800
TWZERO
—
Tweak zero. Adjust the analog output zero calibration. Use a multimeter to monitor the analog
output value. Press and hold
or
to adjust the output.
TWSPAN
—
Tweak span. Adjust the analog output span calibration. Use a multimeter to monitor the analog
output value. Press and hold
or
to adjust the output.
Table 3-9. Analog Output Menu Parameters
XXXXXXX
XXXXXXX
XXXXXXX
Software
version
VERS
ALGOUT
DIG IN
PROGRM
PFORMT
SERIAL
CALIBR
CONFIG
FORMAT
SETPNTS