EDP Commands
41
Command
Description
Values
SETPOINT
Setpoint number
1–8
KIND
Setpoint kind
OFF, GROSSSP, NETSP, –RELSP, PAUSE, DELAY, WAITSS, TIMER,
CONCUR
VALUE
Setpoint value
number
PSHTARE
Push tare
OFF, ON
PSHPRINT
Push print
OFF, ON, WAITSS
PSHACCM
Push accumulate
OFF, ON, ONQUIET
TRIP
Trip
HIGHER, LOWER, INBAND, OUTBAND
BANDVAL
Band value
number
HYSTER
Hysteresis
number
ALARM
Alarm
OFF, ON
PREACT
Preact
OFF, ON, LEARN
PREVAL
Preact value
number
BATCH
Batch step enable
OFF, ON
NAME
Setpoint name number
NONE,
1–16
ACCESS
Setpoint access
OFF, ON, HIDE
DIGOUT
Digital output
NONE,
1–8
RELNUM
Relative setpoint numer
1–8
START
Starting setpoint
1–8
END
Ending setpoint
1–8
BATCHNG
Batching mode
OFF, AUTO, MANUAL
SPNAME#1—
SPNAME#16
Setpoint names
name
Table 5-8. SETPNTS EDP Commands
Command
Description
Values
GFMT
Gross demand print format string
See Section 6.0 on page 45 for detailed information
NFMT
Net demand print format string
SPFMT
Setpoint print format string
TRWIN
Truck weigh-in print format string
TRWOUT
Truck weigh-out print format string
EDPFMT
EDP demand print format string
HDRFMT
Ticket header format string
Table 5-9. PFORMT EDP Commands
Command
Description
DON#
nn
Set digital output
nn
on
DOFF#
nn
Set digital output
nn
off
DOFF#0
Set all digital outputs off
For commands ending with “#
nn
”,
nn
is the digital output (01–8) being set on or off.
Table 5-10. DIG OUT EDP Commands