42
IQ plus 710 Installation Manual
5.1.5
Normal Mode Commands
The normal mode commands (see Table 5-13) transmit data to the EDP port on demand. These commands are
valid only in normal operating mode.
Command
Description
Values
DIGIN1
DIGIN2
DIGIN3
DIGIN4
DIGIN5
DIGIN6
DIGIN7
DIGIN8
Digital input function
OFF, ZERO, NT/GRS, TARE, UNITS, PRINT, ACCUM, SETPNT,
TIMDATE, ESC, ALPHAMD, CLEAR, DSPTAR, IDKEY, KF1–KF4,
KEY0–KEY9, KEYDP, ENTER, BATRUN, BATSTRT, BATPAUS,
KBDLOC, HOLD, CLRCN
Table 5-11. DIG IN EDP Commands
Command
Description
Values
SOURCE1
Analog output source
GROSS, NET
OFFSET
Zero offset
0%, 20%
ERRACT
Error action
FULLSC, HOLD, ZEROSC
MIN
Minimum value tracked
0–9 999 800
MAX
Maximum value tracked
0–9 999 800
ZERO1
Zero calibration
0–16 383
SPAN1
Span calibration
0–16 383
Table 5-12. ALGOUT EDP Commands
Command
Description
Response Format
CONSNUM
Set consecutive number
0–999 999
SD
Set date
MMDDYY
or
DDMMYY
(enter using DATEFMT specified)
ST
Set time
hhmm
(enter using 24-hour format)
SX
Start EDP streaming
OK
or
??
EX
Stop EDP streaming
OK
or
??
DX
Start streaming raw A/D counts
OK
or
??
RS
Reset system
—
XA
Transmit accumulator value
nnnnnn UU
where
nnnnnn
is the weight value,
UU
is the units.
XG
Transmit gross weight in displayed units
XN
Transmit net weight in displayed units
XT
Transmit tare weight in displayed units
XG2
Transmit gross weight in non-displayed units
XN2
Transmit net weight in non-displayed units
XT2
Transmit tare weight in non-displayed units
XE
Query system error conditions
nnnnn nnnnn
See Section 10.1 on page 62 for detailed information about
the XE command response format.
Table 5-13. Normal Mode EDP Commands