20
IQ plus 710 Installation Manual
Primary Units (PRIMAR Parameter)
DECPNT
8888888
8888880
8888800
8.888888
88.88888
888.8888
8888.888
88888.88
888888.8
Decimal point location. Specifies the location of the decimal point or dummy zeroes in the
primary unit display. Value should be consistent with local legal requirements.
DSPDIV
1D
2D
5D
Display divisions. Selects the minimum division size for the primary units displayed weight.
UNITS
LB
KG
G
OZ
TN
T
GN
TROYOZ
TROYLB
LT
NONE
Specifies primary units for displayed and printed weight. Values are: LB=pound;
KG=kilogram; G=gram; OZ=ounce; TN=short ton; T=metric ton; GN=grain; TROYOZ=troy
ounce; TROYLB=troy pound; LT=long ton.
NOTE:
Indicators sold outside North America are configured with
KG
for both primary and
secondary units.
Secondary Units (SECNDR Parameter)
DECPNT
888888.8
8888888
8888880
8888800
8.888888
88.88888
888.8888
8888.888
88888.88
Decimal point location. Determines the location of the decimal point or dummy zeros in the
display.
DSPDIV
5D
1D
2D
Display divisions. Selects the value of minimum division size of the displayed weight.
UNITS
KG
G
OZ
TN
T
GN
TROYOZ
TROYLB
LT
NONE
LB
Specifies primary units for displayed and printed weight. Values are: LB=pound;
KG=kilogram; G=gram; OZ=ounce; TN=short ton; T=metric ton; GN=grain; TROYOZ=troy
ounce; TROYLB=troy pound; LT=long ton.
MULT
0.453592
Enter other
choices via
keyboard
Multiplier. Specifies the conversion factor by which the primary units are multiplied by to
obtain the secondary units. The default is 0.453592, which is the conversion factor for
changing pounds to kilograms. See Section 10.6 on page 67 for a list of multipliers.
To toggle between primary and secondary units, press the UNITS key.
FORMAT Menu
Parameter
Choices
Description
Table 3-3. Format Menu Parameters (Continued)