9
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil
ID Air Mover
Total Capacity
BTU/H [kW]
SEER
EER
025JEZ
RCQD-2417
RBHM-17J
1
17500 [5.1]
3500 [1.0]
25600 [7.5]
16.5
13
600 [283]
71
2
20100 [5.9]
5500 [1.6]
825 [389]
74
RGFE-06?MCK?
1
17000 [5.0]
3600 [1.1]
25600 [7.5]
16.5
13
575 [271]
71
2
20100 [5.9]
5500 [1.6]
800 [378]
74
RGFE-07?MCK?
1
17500 [5.1]
3500 [1.0]
25600 [7.5]
16.5
13
600 [283]
71
2
20100 [5.9]
5500 [1.6]
825 [389]
74
RGFG-06?MCK?
1
17000 [5.0]
3600 [1.1]
25600 [7.5]
16.5
13
575 [271]
71
2
20100 [5.9]
5500 [1.6]
800 [378]
74
RGFG-07?MCK?
1
17500 [5.1]
3500 [1.0]
25400 [7.4]
16.5
13
600 [283]
71
2
19900 [5.8]
5500 [1.6]
850 [401]
74
RGJF-06?MCK?
1
17500 [5.1]
3500 [1.0]
25600 [7.5]
16.5
13
625 [295]
71
2
20100 [5.9]
5500 [1.6]
825 [389]
74
RGJF-07?MCK?
1
17000 [5.0]
3600 [1.1]
25600 [7.5]
16.5
13
575 [271]
71
2
20100 [5.9]
5500 [1.6]
800 [378]
74
RGPE-05?BMK?
1
17000 [5.0]
3600 [1.1]
25600 [7.5]
16.5
13
575 [271]
71
2
20100 [5.9]
5500 [1.6]
800 [378]
74
RGPE-07?AMK?
1
17500 [5.1]
3500 [1.0]
25600 [7.5]
16.5
13
625 [295]
71
2
20100 [5.9]
5500 [1.6]
825 [389]
74
RGRM-04?MAE?
1
17000 [5.0]
3600 [1.1]
25400 [7.4]
16
13
575 [271]
71
2
19900 [5.8]
5500 [1.6]
800 [378]
74
RGRM-06?MAE?
1
17500 [5.1]
3500 [1.0]
25400 [7.4]
16.5
13
600 [283]
71
2
19900 [5.8]
5500 [1.6]
825 [389]
74
RGRM-07?MAE?
1
17300 [5.1]
3500 [1.0]
25400 [7.4]
16
13
625 [295]
71
2
19900 [5.8]
5500 [1.6]
850 [401]
74
RGTM-06?MAE?
1
18500 [5.4]
3100 [0.9]
25600 [7.5]
16.5
13
750 [354]
71
2
20100 [5.9]
5500 [1.6]
825 [389]
74
ROCA-070E03
1
17500 [5.1]
3500 [1.0]
25600 [7.5]
16.5
13
600 [283]
71
2
20100 [5.9]
5500 [1.6]
800 [378]
74
ROLA-070E03
1
17300 [5.1]
3500 [1.0]
25600 [7.5]
16.5
13
600 [283]
71
2
20100 [5.9]
5500 [1.6]
800 [378]
74
RCQD-2417+RXMD-C06
Coil Only
1
16900 [5.0]
3500 [1.0]
25000 [7.3]
14.5
12
625 [295]
71
2
19500 [5.7]
5500 [1.6]
825 [389]
74
RCSL-H*2621
RHPL-HM2421
1
16800 [4.9]
4000 [1.2]
25400 [7.4]
16.5
13
600 [283]
71
2
18900 [5.5]
6500 [1.9]
800 [378]
74
038JEZ
RCSN-H*3624
➀
RHPN-HM3624
1
22400 [6.6]
8600 [2.5]
38000 [11.1]
16.5
13
925 [437]
71
2
27500 [8.1]
10500 [3.1]
1125 [531]
72
1 - dehumid
19000 [5.6]
7400 [2.2]
750 [354]
2 - dehumid
25900 [7.6]
11700 [3.4]
950 [448]
RCFL-H*3617
RGFE-06?MCK?
1
18900 [5.5]
9300 [2.7]
34400 [10.1]
14
11
875 [413]
71
2
23500 [6.9]
10900 [3.2]
1200 [566]
72
RGFE-07?MCK?
1
18900 [5.5]
9300 [2.7]
34400 [10.1]
14
11
875 [413]
71
2
23600 [6.9]
10800 [3.2]
1225 [578]
72
RGFG-06?MCK?
1
17900 [5.2]
9700 [2.8]
33800 [9.9]
14
11.5
725 [342]
71
2
22100 [6.5]
11700 [3.4]
1000 [472]
72
RGFG-07?MCK?
1
18500 [5.4]
9500 [2.8]
33800 [9.9]
14
11.5
800 [378]
71
2
22100 [6.5]
11700 [3.4]
1000 [472]
72
Rev.
5/8/2012
➀
Highest sales volume tested combination required by D.O.E. test procedures.
[ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RARL- JEZ Series
Summary of Contents for Prestige RARL-JEZ Series
Page 33: ...Air Notes RARL JEZ Series 33...
Page 34: ...Air Notes RARL JEZ Series 34...
Page 35: ...Air Notes RARL JEZ Series 35...