5
Air
Performance Data
RARL- JEZ Series
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil
ID Air Mover
Total Capacity
BTU/H [kW]
SEER
EER
025JEZ
RCSN-H*2421
➀
RHPN-HM2421
1
16800 [4.9]
4000 [1.2]
25200 [7.4]
16.5
13
575 [271]
71
2
18900 [5.5]
6300 [1.8]
825 [389]
74
1 - dehumid
11400 [3.3]
5000 [1.5]
450 [212]
2 - dehumid
17100 [5.0]
6700 [2.0]
675 [319]
RCFL-H*2417
RGFE-06?MCK?
1
16000 [4.7]
4200 [1.2]
24800 [7.3]
15.5
12.5
575 [271]
71
2
18300 [5.4]
6500 [1.9]
800 [378]
74
RGFE-07?MCK?
1
16300 [4.8]
4100 [1.2]
24600 [7.2]
16
13
600 [283]
71
2
18100 [5.3]
6500 [1.9]
825 [389]
74
RGFG-06?MCK?
1
16000 [4.7]
4200 [1.2]
24800 [7.3]
15.5
12.5
575 [271]
71
2
18300 [5.4]
6500 [1.9]
800 [378]
74
RGFG-07?MCK?
1
16300 [4.8]
4100 [1.2]
24600 [7.2]
16
12.5
600 [283]
71
2
18100 [5.3]
6500 [1.9]
850 [401]
74
RGGE-06?MCK?
1
16300 [4.8]
4100 [1.2]
24800 [7.3]
16
13
625 [295]
71
2
18300 [5.4]
6500 [1.9]
825 [389]
74
RGGE-07?MCK?
1
16000 [4.7]
4200 [1.2]
24800 [7.3]
15.5
12.5
575 [271]
71
2
18300 [5.4]
6500 [1.9]
800 [378]
74
RGJF-06?MCK?
1
16300 [4.8]
4100 [1.2]
24800 [7.3]
16
13
625 [295]
71
2
18300 [5.4]
6500 [1.9]
825 [389]
74
RGJF-07?MCK?
1
16000 [4.7]
4200 [1.2]
24800 [7.3]
15.5
12.5
575 [271]
71
2
18300 [5.4]
6500 [1.9]
800 [378]
74
RGLE-07?AMK?
1
16300 [4.8]
4100 [1.2]
24800 [7.3]
16
13
600 [283]
71
2
18300 [5.4]
6500 [1.9]
800 [378]
74
RGPE-05?BMK?
1
16000 [4.7]
4200 [1.2]
24800 [7.3]
15.5
12.5
575 [271]
71
2
18300 [5.4]
6500 [1.9]
800 [378]
74
RGPE-07?AMK?
1
16300 [4.8]
4100 [1.2]
24800 [7.3]
16
13
625 [295]
71
2
18300 [5.4]
6500 [1.9]
825 [389]
74
RGRM-04?MAE?
1
15800 [4.6]
4200 [1.2]
24600 [7.2]
15.5
12.5
575 [271]
71
2
18100 [5.3]
6500 [1.9]
800 [378]
74
RGRM-06?MAE?
1
16300 [4.8]
4100 [1.2]
24600 [7.2]
16
12.5
600 [283]
71
2
18100 [5.3]
6500 [1.9]
825 [389]
74
RGRM-07?MAE?
1
16300 [4.8]
4100 [1.2]
24400 [7.1]
15.5
12.5
625 [295]
71
2
17900 [5.2]
6500 [1.9]
850 [401]
74
RGTM-06?MAE?
1
17200 [5.0]
3800 [1.1]
24600 [7.2]
15.5
12.5
750 [354]
71
2
18100 [5.3]
6500 [1.9]
825 [389]
74
ROCA-070E03
1
16300 [4.8]
4100 [1.2]
24800 [7.3]
16
13
600 [283]
71
2
18300 [5.4]
6500 [1.9]
800 [378]
74
ROLA-070E03
1
16300 [4.8]
4100 [1.2]
24800 [7.3]
15.5
12.5
600 [283]
71
2
18300 [5.4]
6500 [1.9]
800 [378]
74
RCFL-H*2417+RXMD-C06
Coil Only
1
15800 [4.6]
4100 [1.2]
24200 [7.1]
14
11.5
625 [295]
71
2
17700 [5.2]
6500 [1.9]
825 [389]
74
RCFL-H*2617
RGFE-06?MCK?
1
16400 [4.8]
4200 [1.2]
25600 [7.5]
16.5
13
575 [271]
71
2
18900 [5.5]
6700 [2.0]
800 [378]
74
RGFE-07?MCK?
1
16900 [5.0]
4100 [1.2]
25600 [7.5]
16.5
13
600 [283]
71
2
18900 [5.5]
6700 [2.0]
825 [389]
74
RGFG-06?MCK?
1
16400 [4.8]
4200 [1.2]
25600 [7.5]
16.5
13
575 [271]
71
2
18900 [5.5]
6700 [2.0]
800 [378]
74
Rev.
5/8/2012
➀
Highest sales volume tested combination required by D.O.E. test procedures.
[ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Summary of Contents for Prestige RARL-JEZ Series
Page 33: ...Air Notes RARL JEZ Series 33...
Page 34: ...Air Notes RARL JEZ Series 34...
Page 35: ...Air Notes RARL JEZ Series 35...