26
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil
ID Air Mover
Total Capacity
BTU/H [kW]
SEER
EER
061JEZ
RCFL-H*6024
RGPE-10?BRM?
1
32900 [9.6]
15600 [4.6]
58000 [17.0]
16
12.5
1225 [578]
76
2
40400 [11.8]
17600 [5.2]
1625 [767]
78
RGPE-12?ARM?
1
32800 [9.6]
15700 [4.6]
58000 [17.0]
16
12.5
1200 [566]
76
2
40400 [11.8]
17600 [5.2]
1625 [767]
78
RGRM-07?YBG?
1
31800 [9.3]
15700 [4.6]
56000 [16.4]
15
11
1200 [566]
76
2
38000 [11.1]
18000 [5.3]
1575 [743]
78
RGRM-09?ZAJ?
1
32400 [9.5]
15600 [4.6]
57000 [16.7]
15.5
11.5
1225 [578]
76
2
39400 [11.5]
17600 [5.2]
1625 [767]
78
RGRM-10?ZAJ?
1
31500 [9.2]
16000 [4.7]
57000 [16.7]
16
11.5
1150 [543]
76
2
39200 [11.5]
17800 [5.2]
1600 [755]
78
RGRM-12?RAJ?
1
32400 [9.5]
15600 [4.6]
57500 [16.8]
16
12
1225 [578]
76
2
39900 [11.7]
17600 [5.2]
1625 [767]
78
RGTM-07?RBG?
1
34100 [10.0]
14900 [4.4]
58000 [17.0]
16
12
1325 [625]
76
2
40800 [12.0]
17200 [5.0]
1675 [790]
78
RGTM-09?ZAJ?
1
33100 [9.7]
15400 [4.5]
57500 [16.8]
16
12
1250 [590]
76
2
39700 [11.6]
17800 [5.2]
1600 [755]
78
RGTM-10?RBJ?
1
33200 [9.7]
15300 [4.5]
58000 [17.0]
16
12.5
1275 [602]
76
2
40800 [12.0]
17200 [5.0]
1675 [790]
78
ROCA-070E04
1
32300 [9.5]
15700 [4.6]
56500 [16.6]
16
12
1200 [566]
76
2
37100 [10.9]
19400 [5.7]
1400 [661]
78
ROLA-070E04
1
32100 [9.4]
15900 [4.7]
57500 [16.8]
16
12
1175 [554]
76
2
39700 [11.6]
17800 [5.2]
1600 [755]
78
ROLA-115E05
1
32800 [9.6]
15700 [4.6]
57500 [16.8]
16
12.5
1200 [566]
76
2
39700 [11.6]
17800 [5.2]
1600 [755]
78
RCFL-H*6024+RXMD-C06
Coil Only
1
33100 [9.7]
14900 [4.4]
58000 [17.0]
15
12
1325 [625]
76
2
40800 [12.0]
17200 [5.0]
1675 [790]
78
RCFN-H*6024
RGFE-09?ZCM?
1
32300 [9.5]
15700 [4.6]
57500 [16.8]
16
12
1200 [566]
76
2
39700 [11.6]
17800 [5.2]
1600 [755]
78
RGFE-10?ZCM?
1
32400 [9.5]
15600 [4.6]
57000 [16.7]
16
12
1225 [578]
76
2
39200 [11.5]
17800 [5.2]
1600 [755]
78
RGFE-12?RCM?
1
32900 [9.6]
15600 [4.6]
57500 [16.8]
16
12
1225 [578]
76
2
39900 [11.7]
17600 [5.2]
1625 [767]
78
RGFG-09?ZCM?
1
32300 [9.5]
15700 [4.6]
57500 [16.8]
16
12
1200 [566]
76
2
39700 [11.6]
17800 [5.2]
1600 [755]
78
RGFG-10?ZCM?
1
32300 [9.5]
15700 [4.6]
57500 [16.8]
16
12
1200 [566]
76
2
40100 [11.7]
17400 [5.1]
1650 [779]
78
RGFG-12?RCM?
1
32900 [9.6]
15600 [4.6]
57500 [16.8]
16
12
1225 [578]
76
2
39900 [11.7]
17600 [5.2]
1625 [767]
78
RGGE-10?ZCM?
1
32300 [9.5]
15700 [4.6]
57500 [16.8]
16
12
1200 [566]
76
2
39700 [11.6]
17800 [5.2]
1600 [755]
78
RGGE-12?RCM?
1
34400 [10.1]
14600 [4.3]
58500 [17.1]
16
12
1375 [649]
76
2
42200 [12.4]
16300 [4.8]
1750 [826]
78
RGJF-09?ZCM?
1
32900 [9.6]
15600 [4.6]
57500 [16.8]
16
12
1225 [578]
76
2
39700 [11.6]
17800 [5.2]
1600 [755]
78
RGJF-10?ZCM?
1
32300 [9.5]
15700 [4.6]
57500 [16.8]
16
12
1200 [566]
76
2
39700 [11.6]
17800 [5.2]
1600 [755]
78
Rev.
5/8/2012
➀
Highest sales volume tested combination required by D.O.E. test procedures.
[ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RARL- JEZ Series
Summary of Contents for Prestige RARL-JEZ Series
Page 33: ...Air Notes RARL JEZ Series 33...
Page 34: ...Air Notes RARL JEZ Series 34...