22
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil
ID Air Mover
Total Capacity
BTU/H [kW]
SEER
EER
049JEZ
RCFL-H*4824
RGTM-09?ZAJ?
1
24500 [7.2]
14000 [4.1]
44500 [13.0]
15
11.5
1100 [519]
72
2
28200 [8.3]
16300 [4.8]
1400 [661]
72
RGTM-10?RBJ?
1
24600 [7.2]
13900 [4.1]
45000 [13.2]
15
11.5
1125 [531]
72
2
28900 [8.5]
16100 [4.7]
1425 [672]
72
ROCA-070E04
1
25000 [7.3]
13500 [4.0]
44500 [13.0]
14.5
11
1200 [566]
72
2
28200 [8.3]
16300 [4.8]
1400 [661]
72
ROLA-070E04
1
24800 [7.3]
13700 [4.0]
45000 [13.2]
15
11
1175 [554]
72
2
29900 [8.8]
15100 [4.4]
1600 [755]
72
ROLA-115E05
1
23800 [7.0]
14200 [4.2]
44500 [13.0]
15
11.5
1050 [495]
72
2
28200 [8.3]
16300 [4.8]
1400 [661]
72
RCFL-H*4824+RXMD-C06
Coil Only
1
25200 [7.4]
13300 [3.9]
45500 [13.3]
14
11
1250 [590]
72
2
30400 [8.9]
15100 [4.4]
1425 [672]
72
RCFN-H*4824
RGFE-09?ZCM?
1
27700 [8.1]
13300 [3.9]
48500 [14.2]
16.5
12
1025 [484]
72
2
33900 [9.9]
14600 [4.3]
1400 [661]
72
RGFE-10?ZCM?
1
27700 [8.1]
13300 [3.9]
48500 [14.2]
16.5
12
1025 [484]
72
2
34000 [10.0]
14500 [4.2]
1425 [672]
72
RGFE-12?RCM?
1
27700 [8.1]
13300 [3.9]
49000 [14.4]
16.5
12.5
1025 [484]
72
2
34700 [10.2]
14300 [4.2]
1450 [684]
72
RGFG-09?ZCM?
1
27700 [8.1]
13300 [3.9]
48500 [14.2]
16.5
12
1025 [484]
72
2
33900 [9.9]
14600 [4.3]
1400 [661]
72
RGFG-10?ZCM?
1
27800 [8.1]
13200 [3.9]
48500 [14.2]
16
12
1050 [495]
72
2
33900 [9.9]
14600 [4.3]
1400 [661]
72
RGFG-12?RCM?
1
27700 [8.1]
13300 [3.9]
49000 [14.4]
16.5
12.5
1025 [484]
72
2
34700 [10.2]
14300 [4.2]
1450 [684]
72
RGGE-09?ZCM?
1
27700 [8.1]
13300 [3.9]
48500 [14.2]
16.5
12.5
1025 [484]
72
2
33900 [9.9]
14600 [4.3]
1400 [661]
72
RGGE-10?ZCM?
1
27800 [8.1]
13200 [3.9]
48500 [14.2]
16.5
12
1050 [495]
72
2
33900 [9.9]
14600 [4.3]
1400 [661]
72
RGGE-12?RCM?
1
29600 [8.7]
12400 [3.6]
49500 [14.5]
16.5
12.5
1200 [566]
72
2
36200 [10.6]
13300 [3.9]
1575 [743]
72
RGJF-09?ZCM?
1
27700 [8.1]
13300 [3.9]
48500 [14.2]
16.5
12.5
1025 [484]
72
2
33900 [9.9]
14600 [4.3]
1400 [661]
72
RGJF-10?ZCM?
1
27800 [8.1]
13200 [3.9]
48500 [14.2]
16.5
12
1050 [495]
72
2
33900 [9.9]
14600 [4.3]
1400 [661]
72
RGJF-12?RCM?
1
29600 [8.7]
12400 [3.6]
49500 [14.5]
16.5
12.5
1200 [566]
72
2
36200 [10.6]
13300 [3.9]
1575 [743]
72
RGLE-07?BRQ?
1
27700 [8.1]
13300 [3.9]
49000 [14.4]
16.5
12.5
1025 [484]
72
2
34400 [10.1]
14600 [4.3]
1400 [661]
72
RGLE-10?BRM?
1
27800 [8.1]
13200 [3.9]
49000 [14.4]
16.5
12.5
1050 [495]
72
2
34400 [10.1]
14600 [4.3]
1400 [661]
72
RGLE-12?ARM?
1
28500 [8.4]
13000 [3.8]
49000 [14.4]
16.5
12.5
1075 [507]
72
2
34500 [10.1]
14500 [4.2]
1425 [672]
72
RGPE-07?BRQ?
1
27800 [8.1]
13200 [3.9]
49000 [14.4]
16.5
12.5
1050 [495]
72
2
34400 [10.1]
14600 [4.3]
1400 [661]
72
RGPE-10?BRM?
1
28500 [8.4]
13000 [3.8]
49000 [14.4]
16.5
12.5
1075 [507]
72
2
34400 [10.1]
14600 [4.3]
1400 [661]
72
Rev.
5/8/2012
➀
Highest sales volume tested combination required by D.O.E. test procedures.
[ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RARL- JEZ Series
Summary of Contents for Prestige RARL-JEZ Series
Page 33: ...Air Notes RARL JEZ Series 33...
Page 34: ...Air Notes RARL JEZ Series 34...