
17
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil
ID Air Mover
Total Capacity
BTU/H [kW]
SEER
EER
038JEZ
RCFN-H*3624
ROCA-070E03
1
21100 [6.2]
9100 [2.7]
37400 [11.0]
16
13
800 [378]
71
2
26300 [7.7]
11100 [3.3]
1000 [472]
72
ROCA-070E04
1
21100 [6.2]
9100 [2.7]
37400 [11.0]
16
13
800 [378]
71
2
26300 [7.7]
11100 [3.3]
1000 [472]
72
ROLA-070E03
1
22200 [6.5]
8600 [2.5]
38000 [11.1]
16
13
900 [425]
71
2
27700 [8.1]
10300 [3.0]
1175 [554]
72
ROLA-070E04
1
22200 [6.5]
8600 [2.5]
38000 [11.1]
16
13
900 [425]
71
2
27700 [8.1]
10300 [3.0]
1175 [554]
72
ROLA-115E05
1
22200 [6.5]
8600 [2.5]
38500 [11.3]
16.5
13
900 [425]
71
2
28300 [8.3]
10200 [3.0]
1200 [566]
72
RCFN-H*3624+RXMD-C06
Coil Only
1
21400 [6.3]
8600 [2.5]
37400 [11.0]
14
12
925 [437]
71
2
26900 [7.9]
10500 [3.1]
1125 [531]
72
RCQD-3621
RGFE-06?MCK?
1
19900 [5.8]
9100 [2.7]
36600 [10.7]
15.5
12.5
725 [342]
71
2
25600 [7.5]
11000 [3.2]
1000 [472]
72
RGFE-07?MCK?
1
19900 [5.8]
9100 [2.7]
36600 [10.7]
15.5
12.5
725 [342]
71
2
25700 [7.5]
10900 [3.2]
1025 [484]
72
RGFE-09?ZCM?
1
21200 [6.2]
8600 [2.5]
37600 [11.0]
15.5
12.5
875 [413]
71
2
27500 [8.1]
10100 [3.0]
1200 [566]
72
RGFE-10?ZCM?
1
21800 [6.4]
8400 [2.5]
37600 [11.0]
15.5
12.5
900 [425]
71
2
27600 [8.1]
10000 [2.9]
1225 [578]
72
RGFG-06?MCK?
1
19900 [5.8]
9100 [2.7]
36600 [10.7]
15.5
12.5
725 [342]
71
2
25600 [7.5]
11000 [3.2]
1000 [472]
72
RGFG-07?MCK?
1
20500 [6.0]
8900 [2.6]
36400 [10.7]
15.5
12.5
800 [378]
71
2
25400 [7.4]
11000 [3.2]
1000 [472]
72
RGFG-09?ZCM?
1
21200 [6.2]
8600 [2.5]
37600 [11.0]
15.5
12.5
875 [413]
71
2
27500 [8.1]
10100 [3.0]
1200 [566]
72
RGFG-10?ZCM?
1
21800 [6.4]
8400 [2.5]
37600 [11.0]
15.5
12.5
900 [425]
71
2
27500 [8.1]
10100 [3.0]
1200 [566]
72
RGJF-06?MCK?
1
21600 [6.3]
8400 [2.5]
37400 [11.0]
15.5
12.5
925 [437]
71
2
27300 [8.0]
10100 [3.0]
1200 [566]
72
RGJF-07?MCK?
1
20200 [5.9]
9000 [2.6]
36600 [10.7]
15.5
12.5
750 [354]
71
2
25700 [7.5]
10900 [3.2]
1025 [484]
72
RGJF-09?ZCM?
1
21200 [6.2]
8600 [2.5]
37800 [11.1]
15.5
12.5
875 [413]
71
2
27800 [8.1]
10000 [2.9]
1225 [578]
72
RGJF-10?ZCM?
1
21200 [6.2]
8600 [2.5]
37600 [11.0]
15.5
12.5
875 [413]
71
2
27500 [8.1]
10100 [3.0]
1200 [566]
72
RGPE-05?BMK?
1
21600 [6.3]
8400 [2.5]
37400 [11.0]
15.5
12
900 [425]
71
2
27300 [8.0]
10100 [3.0]
1200 [566]
72
RGPE-07?AMK?
1
21800 [6.4]
8400 [2.5]
37600 [11.0]
15.5
12.5
900 [425]
71
2
27600 [8.1]
10000 [2.9]
1225 [578]
72
RGPE-07?BRQ?
1
21800 [6.4]
8400 [2.5]
38000 [11.1]
16
13
900 [425]
71
2
28000 [8.2]
10000 [2.9]
1225 [578]
72
RGPE-10?BRM?
1
21800 [6.4]
8400 [2.5]
38000 [11.1]
16
13
900 [425]
71
2
28000 [8.2]
10000 [2.9]
1225 [578]
72
RGRM-04?MAE?
1
20200 [5.9]
9000 [2.6]
36600 [10.7]
15.5
12.5
750 [354]
71
2
25700 [7.5]
10900 [3.2]
1025 [484]
72
Rev.
5/8/2012
➀
Highest sales volume tested combination required by D.O.E. test procedures.
[ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RARL- JEZ Series
Summary of Contents for Prestige RARL-JEZ Series
Page 33: ...Air Notes RARL JEZ Series 33...
Page 34: ...Air Notes RARL JEZ Series 34...
Page 35: ...Air Notes RARL JEZ Series 35...