13
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil
ID Air Mover
Total Capacity
BTU/H [kW]
SEER
EER
038JEZ
RCFL-H*3821
RGLE-07?BRQ?
1
18400 [5.4]
9800 [2.9]
35000 [10.3]
15.1
12.5
775 [366]
71
2
23200 [6.8]
11800 [3.5]
1025 [484]
72
RGLE-10?BRM?
1
19200 [5.6]
9600 [2.8]
35800 [10.5]
15.1
12.5
875 [413]
71
2
24700 [7.2]
11100 [3.3]
1200 [566]
72
RGPE-05?BMK?
1
19400 [5.7]
9400 [2.8]
35200 [10.3]
14.5
11.5
900 [425]
71
2
24100 [7.1]
11100 [3.3]
1200 [566]
72
RGPE-07?AMK?
1
19600 [5.7]
9400 [2.8]
35600 [10.4]
14.5
12
900 [425]
71
2
24600 [7.2]
11000 [3.2]
1225 [578]
72
RGPE-07?BRQ?
1
19600 [5.7]
9400 [2.8]
35800 [10.5]
15.1
12.5
900 [425]
71
2
24800 [7.3]
11000 [3.2]
1225 [578]
72
RGPE-10?BRM?
1
19600 [5.7]
9400 [2.8]
35800 [10.5]
15.1
12.5
900 [425]
71
2
24800 [7.3]
11000 [3.2]
1225 [578]
72
RGRM-04?MAE?
1
18100 [5.3]
9900 [2.9]
34600 [10.1]
14.5
11.5
750 [354]
71
2
22800 [6.7]
11800 [3.5]
1025 [484]
72
RGRM-06?MAE?
1
18400 [5.4]
9800 [2.9]
34400 [10.1]
14.5
12
775 [366]
71
2
22500 [6.6]
11900 [3.5]
1000 [472]
72
RGRM-07?MAE?
1
18400 [5.4]
9800 [2.9]
34400 [10.1]
14.5
11.5
800 [378]
71
2
22600 [6.6]
11800 [3.5]
1025 [484]
72
RGRM-07?YBG?
1
18800 [5.5]
9600 [2.8]
34800 [10.2]
14
11
850 [401]
71
2
23700 [6.9]
11100 [3.3]
1200 [566]
72
RGRM-09?ZAJ?
1
19400 [5.7]
9400 [2.8]
35400 [10.4]
14.5
11.5
950 [448]
71
2
24400 [7.1]
11000 [3.2]
1225 [578]
72
RGRM-10?ZAJ?
1
19000 [5.6]
9600 [2.8]
35000 [10.3]
14.5
12
875 [413]
71
2
23600 [6.9]
11400 [3.3]
1150 [543]
72
RGTM-06?MAE?
1
19400 [5.7]
9400 [2.8]
34600 [10.1]
14.5
12
900 [425]
71
2
22800 [6.7]
11800 [3.5]
1025 [484]
72
RGTM-07?RBG?
1
18600 [5.4]
9800 [2.9]
35000 [10.3]
15
12.5
800 [378]
71
2
23300 [6.8]
11700 [3.4]
1050 [495]
72
RGTM-09?ZAJ?
1
19900 [5.8]
9300 [2.7]
35600 [10.4]
15
12
975 [460]
71
2
24600 [7.2]
11000 [3.2]
1225 [578]
72
ROCA-070E03
1
18600 [5.4]
9800 [2.9]
34600 [10.1]
15
12
800 [378]
71
2
22700 [6.7]
11900 [3.5]
1000 [472]
72
ROCA-070E04
1
18600 [5.4]
9800 [2.9]
34600 [10.1]
15
12
800 [378]
71
2
22700 [6.7]
11900 [3.5]
1000 [472]
72
ROLA-070E03
1
19600 [5.7]
9400 [2.8]
35600 [10.4]
15
12
900 [425]
71
2
24400 [7.1]
11200 [3.3]
1175 [554]
72
ROLA-070E04
1
19600 [5.7]
9400 [2.8]
35600 [10.4]
15
12
900 [425]
71
2
24400 [7.1]
11200 [3.3]
1175 [554]
72
ROLA-115E05
1
19600 [5.7]
9400 [2.8]
35600 [10.4]
15.1
12.5
900 [425]
71
2
24500 [7.2]
11100 [3.3]
1200 [566]
72
RCFL-H*3821+RXMD-C06
Coil Only
1
18800 [5.5]
9400 [2.8]
34800 [10.2]
13
11.5
925 [437]
71
2
23400 [6.9]
11400 [3.3]
1125 [531]
72
RCFL-H*3824
RGFE-09?ZCM?
1
19000 [5.6]
9600 [2.8]
35400 [10.4]
14.5
12
875 [413]
71
2
24300 [7.1]
11100 [3.3]
1200 [566]
72
RGFE-10?ZCM?
1
19600 [5.7]
9400 [2.8]
35600 [10.4]
15
12
900 [425]
71
2
24600 [7.2]
11000 [3.2]
1225 [578]
72
Rev.
5/8/2012
➀
Highest sales volume tested combination required by D.O.E. test procedures.
[ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RARL- JEZ Series
Summary of Contents for Prestige RARL-JEZ Series
Page 33: ...Air Notes RARL JEZ Series 33...
Page 34: ...Air Notes RARL JEZ Series 34...