18
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil
ID Air Mover
Total Capacity
BTU/H [kW]
SEER
EER
038JEZ
RCQD-3621
RGRM-06?MAE?
1
20500 [6.0]
8900 [2.6]
36400 [10.7]
15.5
12.5
775 [366]
71
2
25400 [7.4]
11000 [3.2]
1000 [472]
72
RGRM-07?MAE?
1
20500 [6.0]
8900 [2.6]
36400 [10.7]
15
12
800 [378]
71
2
25500 [7.5]
10900 [3.2]
1025 [484]
72
RGRM-07?YBG?
1
20900 [6.1]
8700 [2.5]
37000 [10.8]
15
11.5
850 [401]
71
2
26900 [7.9]
10100 [3.0]
1200 [566]
72
RGRM-09?ZAJ?
1
21600 [6.3]
8400 [2.5]
37600 [11.0]
15.5
12.5
950 [448]
71
2
27600 [8.1]
10000 [2.9]
1225 [578]
72
RGRM-10?ZAJ?
1
21200 [6.2]
8600 [2.5]
37000 [10.8]
15.5
12.5
875 [413]
71
2
26600 [7.8]
10400 [3.0]
1150 [543]
72
RGTM-06?MAE?
1
21600 [6.3]
8400 [2.5]
36600 [10.7]
15.5
12.5
900 [425]
71
2
25700 [7.5]
10900 [3.2]
1025 [484]
72
RGTM-07?RBG?
1
20500 [6.0]
8900 [2.6]
37000 [10.8]
15.5
13
800 [378]
71
2
26200 [7.7]
10800 [3.2]
1050 [495]
72
RGTM-09?ZAJ?
1
22100 [6.5]
8300 [2.4]
37800 [11.1]
15.5
12.5
975 [460]
71
2
27800 [8.1]
10000 [2.9]
1225 [578]
72
ROCA-070E03
1
20500 [6.0]
8900 [2.6]
36600 [10.7]
15.5
13
800 [378]
71
2
25600 [7.5]
11000 [3.2]
1000 [472]
72
ROCA-070E04
1
20500 [6.0]
8900 [2.6]
36600 [10.7]
15.5
13
800 [378]
71
2
25600 [7.5]
11000 [3.2]
1000 [472]
72
ROLA-070E03
1
21800 [6.4]
8400 [2.5]
37600 [11.0]
15.5
13
900 [425]
71
2
27400 [8.0]
10200 [3.0]
1175 [554]
72
ROLA-070E04
1
21800 [6.4]
8400 [2.5]
37600 [11.0]
15.5
13
900 [425]
71
2
27400 [8.0]
10200 [3.0]
1175 [554]
72
ROLA-115E05
1
21800 [6.4]
8400 [2.5]
37800 [11.1]
16
13
900 [425]
71
2
27700 [8.1]
10100 [3.0]
1200 [566]
72
RCQD-3621+RXMD-C06
Coil Only
1
21000 [6.2]
8400 [2.5]
36800 [10.8]
14
12
925 [437]
71
2
26400 [7.7]
10400 [3.0]
1125 [531]
72
RCQD-3624
RBHM-24J
1
21800 [6.4]
8400 [2.5]
37800 [11.1]
16
13
900 [425]
71
2
27600 [8.1]
10200 [3.0]
1175 [554]
72
RBHN-24J
1
21800 [6.4]
8400 [2.5]
38000 [11.1]
16.5
13
925 [437]
71
2
27800 [8.1]
10200 [3.0]
1175 [554]
72
RGFE-09?ZCM?
1
21200 [6.2]
8600 [2.5]
37600 [11.0]
15.5
12.5
875 [413]
71
2
27500 [8.1]
10100 [3.0]
1200 [566]
72
RGFE-10?ZCM?
1
21800 [6.4]
8400 [2.5]
37800 [11.1]
16
12.5
900 [425]
71
2
27800 [8.1]
10000 [2.9]
1225 [578]
72
RGFE-12?RCM?
1
21400 [6.3]
8600 [2.5]
37800 [11.1]
16
13
875 [413]
71
2
27800 [8.1]
10000 [2.9]
1225 [578]
72
RGFG-09?ZCM?
1
21200 [6.2]
8600 [2.5]
37600 [11.0]
15.5
12.5
875 [413]
71
2
27500 [8.1]
10100 [3.0]
1200 [566]
72
RGFG-10?ZCM?
1
21800 [6.4]
8400 [2.5]
37600 [11.0]
15.5
12.5
900 [425]
71
2
27500 [8.1]
10100 [3.0]
1200 [566]
72
RGFG-12?RCM?
1
21400 [6.3]
8600 [2.5]
37800 [11.1]
16
13
875 [413]
71
2
27800 [8.1]
10000 [2.9]
1225 [578]
72
RGJF-09?ZCM?
1
21200 [6.2]
8600 [2.5]
37800 [11.1]
15.5
13
875 [413]
71
2
27800 [8.1]
10000 [2.9]
1225 [578]
72
Rev.
5/8/2012
➀
Highest sales volume tested combination required by D.O.E. test procedures.
[ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RARL- JEZ Series
Summary of Contents for Prestige RARL-JEZ Series
Page 33: ...Air Notes RARL JEZ Series 33...
Page 34: ...Air Notes RARL JEZ Series 34...