16
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil
ID Air Mover
Total Capacity
BTU/H [kW]
SEER
EER
038JEZ
RCFN-H*3624
RGJF-09?ZCM?
1
21800 [6.4]
8800 [2.6]
38500 [11.3]
16
13
875 [413]
71
2
28400 [8.3]
10100 [3.0]
1225 [578]
72
RGJF-10?ZCM?
1
21800 [6.4]
8800 [2.6]
38000 [11.1]
16
13
875 [413]
71
2
27800 [8.1]
10200 [3.0]
1200 [566]
72
RGJF-12?RCM?
1
21800 [6.4]
8800 [2.6]
38500 [11.3]
16.5
13
875 [413]
71
2
28300 [8.3]
10200 [3.0]
1200 [566]
72
RGLE-07?AMK?
1
20600 [6.0]
9200 [2.7]
37400 [11.0]
16
13
750 [354]
71
2
26400 [7.7]
11000 [3.2]
1025 [484]
72
RGLE-07?BRQ?
1
22200 [6.5]
8600 [2.5]
38500 [11.3]
16.5
13
925 [437]
71
2
28400 [8.3]
10100 [3.0]
1225 [578]
72
RGLE-10?BRM?
1
21800 [6.4]
8800 [2.6]
38500 [11.3]
16.5
13
875 [413]
71
2
28300 [8.3]
10200 [3.0]
1200 [566]
72
RGLE-12?ARM?
1
22400 [6.6]
8600 [2.5]
38500 [11.3]
16.5
13
925 [437]
71
2
28400 [8.3]
10100 [3.0]
1225 [578]
72
RGPE-05?BMK?
1
22200 [6.5]
8600 [2.5]
38000 [11.1]
16
12.5
900 [425]
71
2
27800 [8.1]
10200 [3.0]
1200 [566]
72
RGPE-07?AMK?
1
20500 [6.0]
9300 [2.7]
37400 [11.0]
16
13
725 [342]
71
2
26300 [7.7]
11100 [3.3]
1000 [472]
72
RGPE-07?BRQ?
1
22400 [6.6]
8600 [2.5]
38500 [11.3]
16.5
13
900 [425]
71
2
28400 [8.3]
10100 [3.0]
1225 [578]
72
RGPE-10?BRM?
1
22400 [6.6]
8600 [2.5]
38500 [11.3]
16.5
13
900 [425]
71
2
28400 [8.3]
10100 [3.0]
1225 [578]
72
RGPE-12?ARM?
1
21800 [6.4]
8800 [2.6]
38500 [11.3]
16.5
13
875 [413]
71
2
28300 [8.3]
10200 [3.0]
1200 [566]
72
RGRM-04?MAE?
1
20600 [6.0]
9200 [2.7]
37200 [10.9]
16
12.5
750 [354]
71
2
26200 [7.7]
11000 [3.2]
1025 [484]
72
RGRM-06?MAE?
1
20900 [6.1]
9100 [2.7]
37000 [10.8]
16
12.5
775 [366]
71
2
25900 [7.6]
11100 [3.3]
1000 [472]
72
RGRM-07?MAE?
1
20900 [6.1]
9100 [2.7]
37000 [10.8]
15.5
12
800 [378]
71
2
26000 [7.6]
11000 [3.2]
1025 [484]
72
RGRM-07?YBG?
1
21300 [6.2]
8900 [2.6]
37600 [11.0]
15.5
12
850 [401]
71
2
27400 [8.0]
10200 [3.0]
1200 [566]
72
RGRM-09?ZAJ?
1
22200 [6.5]
8600 [2.5]
38000 [11.1]
16
12.5
950 [448]
71
2
27900 [8.2]
10100 [3.0]
1225 [578]
72
RGRM-10?ZAJ?
1
21800 [6.4]
8800 [2.6]
37800 [11.1]
16
12.5
875 [413]
71
2
27300 [8.0]
10500 [3.1]
1150 [543]
72
RGRM-12?RAJ?
1
22200 [6.5]
8600 [2.5]
38500 [11.3]
16
13
925 [437]
71
2
28400 [8.3]
10100 [3.0]
1225 [578]
72
RGTM-06?MAE?
1
22200 [6.5]
8600 [2.5]
37400 [11.0]
16
12.5
900 [425]
71
2
26400 [7.7]
11000 [3.2]
1025 [484]
72
RGTM-07?RBG?
1
22200 [6.5]
8600 [2.5]
38500 [11.3]
16
13
950 [448]
71
2
28700 [8.4]
9800 [2.9]
1275 [602]
72
RGTM-09?ZAJ?
1
22500 [6.6]
8500 [2.5]
38500 [11.3]
16
13
975 [460]
71
2
28400 [8.3]
10100 [3.0]
1225 [578]
72
RGTM-10?RBJ?
1
22700 [6.7]
8500 [2.5]
38500 [11.3]
16
13
975 [460]
71
2
28400 [8.3]
10100 [3.0]
1225 [578]
72
Rev.
5/8/2012
➀
Highest sales volume tested combination required by D.O.E. test procedures.
[ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RARL- JEZ Series
Summary of Contents for Prestige RARL-JEZ Series
Page 33: ...Air Notes RARL JEZ Series 33...
Page 34: ...Air Notes RARL JEZ Series 34...