25
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil
ID Air Mover
Total Capacity
BTU/H [kW]
SEER
EER
049JEZ
RCQD-4824
ROCA-070E04
1
28900 [8.5]
11600 [3.4]
46500 [13.6]
15.5
11.5
1200 [566]
72
2
32600 [9.6]
13900 [4.1]
1400 [661]
72
ROLA-070E04
1
28700 [8.4]
11800 [3.5]
47500 [13.9]
16
11.5
1175 [554]
72
2
35000 [10.3]
12500 [3.7]
1600 [755]
72
ROLA-115E05
1
27600 [8.1]
12400 [3.6]
47000 [13.8]
16
12
1050 [495]
72
2
33100 [9.7]
13900 [4.1]
1400 [661]
72
RCQD-4824+RXMD-C06
Coil Only
1
28600 [8.4]
11400 [3.3]
47500 [13.9]
14.5
11.5
1250 [590]
72
2
35000 [10.3]
12500 [3.7]
1600 [755]
72
RCSL-H*4824
RHPL-HM4824
1
26200 [7.7]
13300 [3.9]
46000 [13.5]
16
12
1250 [590]
72
2
30900 [9.1]
15100 [4.4]
1625 [767]
72
061JEZ
RCSN-H*6024
➀
RHPN-HM6024
1
34100 [10.0]
14900 [4.4]
59000 [17.3]
16
13
1325 [625]
76
2
42700 [12.5]
16300 [4.8]
1775 [838]
78
1 - dehumid
29000 [8.5]
12500 [3.7]
1050 [495]
2 - dehumid
39300 [11.5]
18200 [5.3]
1450 [684]
RCFL-H*6024
RGFE-09?ZCM?
1
32300 [9.5]
15700 [4.6]
57500 [16.8]
16
12
1200 [566]
76
2
39700 [11.6]
17800 [5.2]
1600 [755]
78
RGFE-10?ZCM?
1
32400 [9.5]
15600 [4.6]
57000 [16.7]
16
12
1225 [578]
76
2
39200 [11.5]
17800 [5.2]
1600 [755]
78
RGFE-12?RCM?
1
32900 [9.6]
15600 [4.6]
57500 [16.8]
16
12
1225 [578]
76
2
39900 [11.7]
17600 [5.2]
1625 [767]
78
RGFG-09?ZCM?
1
32300 [9.5]
15700 [4.6]
57500 [16.8]
16
12
1200 [566]
76
2
39700 [11.6]
17800 [5.2]
1600 [755]
78
RGFG-10?ZCM?
1
32300 [9.5]
15700 [4.6]
57500 [16.8]
16
12
1200 [566]
76
2
40100 [11.7]
17400 [5.1]
1650 [779]
78
RGFG-12?RCM?
1
32900 [9.6]
15600 [4.6]
57500 [16.8]
16
12
1225 [578]
76
2
39900 [11.7]
17600 [5.2]
1625 [767]
78
RGGE-09?ZCM?
1
32900 [9.6]
15600 [4.6]
57500 [16.8]
16
12
1225 [578]
76
2
39700 [11.6]
17800 [5.2]
1600 [755]
78
RGGE-10?ZCM?
1
32300 [9.5]
15700 [4.6]
57500 [16.8]
16
12
1200 [566]
76
2
39700 [11.6]
17800 [5.2]
1600 [755]
78
RGGE-12?RCM?
1
34400 [10.1]
14600 [4.3]
58500 [17.1]
16
12
1375 [649]
76
2
42100 [12.3]
16400 [4.8]
1750 [826]
78
RGJF-09?ZCM?
1
32900 [9.6]
15600 [4.6]
57500 [16.8]
16
12
1225 [578]
76
2
39700 [11.6]
17800 [5.2]
1600 [755]
78
RGJF-10?ZCM?
1
32300 [9.5]
15700 [4.6]
57500 [16.8]
16
12
1200 [566]
76
2
39700 [11.6]
17800 [5.2]
1600 [755]
78
RGJF-12?RCM?
1
34400 [10.1]
14600 [4.3]
58500 [17.1]
16
12
1375 [649]
76
2
42100 [12.3]
16400 [4.8]
1750 [826]
78
RGLE-07?BRQ?
1
32900 [9.6]
15600 [4.6]
57500 [16.8]
16
12.5
1225 [578]
76
2
39700 [11.6]
17800 [5.2]
1600 [755]
78
RGLE-10?BRM?
1
32800 [9.6]
15700 [4.6]
58000 [17.0]
16
12.5
1200 [566]
76
2
40200 [11.8]
17800 [5.2]
1600 [755]
78
RGLE-12?ARM?
1
32900 [9.6]
15600 [4.6]
58000 [17.0]
16
12.5
1225 [578]
76
2
40200 [11.8]
17800 [5.2]
1600 [755]
78
RGPE-07?BRQ?
1
32900 [9.6]
15600 [4.6]
58000 [17.0]
16
12.5
1225 [578]
76
2
40200 [11.8]
17800 [5.2]
1600 [755]
78
Rev.
5/8/2012
➀
Highest sales volume tested combination required by D.O.E. test procedures.
[ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RARL- JEZ Series
Summary of Contents for Prestige RARL-JEZ Series
Page 33: ...Air Notes RARL JEZ Series 33...
Page 34: ...Air Notes RARL JEZ Series 34...