14
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil
ID Air Mover
Total Capacity
BTU/H [kW]
SEER
EER
038JEZ
RCFL-H*3824
RGFE-12?RCM?
1
19200 [5.6]
9600 [2.8]
35800 [10.5]
15
12
875 [413]
71
2
24800 [7.3]
11000 [3.2]
1225 [578]
72
RGFG-09?ZCM?
1
19000 [5.6]
9600 [2.8]
35400 [10.4]
14.5
12
875 [413]
71
2
24300 [7.1]
11100 [3.3]
1200 [566]
72
RGFG-10?ZCM?
1
19600 [5.7]
9400 [2.8]
35400 [10.4]
15
12
900 [425]
71
2
24300 [7.1]
11100 [3.3]
1200 [566]
72
RGFG-12?RCM?
1
19200 [5.6]
9600 [2.8]
35800 [10.5]
15
12
875 [413]
71
2
24800 [7.3]
11000 [3.2]
1225 [578]
72
RGGE-09?ZCM?
1
19000 [5.6]
9600 [2.8]
35600 [10.4]
15
12
875 [413]
71
2
24600 [7.2]
11000 [3.2]
1225 [578]
72
RGGE-10?ZCM?
1
19000 [5.6]
9600 [2.8]
35400 [10.4]
14.5
12
875 [413]
71
2
24300 [7.1]
11100 [3.3]
1200 [566]
72
RGGE-12?RCM?
1
19200 [5.6]
9600 [2.8]
35800 [10.5]
15.1
12.5
875 [413]
71
2
24700 [7.2]
11100 [3.3]
1200 [566]
72
RGJF-09?ZCM?
1
19000 [5.6]
9600 [2.8]
35800 [10.5]
15
12
875 [413]
71
2
24800 [7.3]
11000 [3.2]
1225 [578]
72
RGJF-10?ZCM?
1
19000 [5.6]
9600 [2.8]
35600 [10.4]
14.5
12
875 [413]
71
2
24500 [7.2]
11100 [3.3]
1200 [566]
72
RGJF-12?RCM?
1
19200 [5.6]
9600 [2.8]
35800 [10.5]
15.1
12.5
875 [413]
71
2
24700 [7.2]
11100 [3.3]
1200 [566]
72
RGLE-07?BRQ?
1
18400 [5.4]
9800 [2.9]
35000 [10.3]
15.1
12.5
775 [366]
71
2
23200 [6.8]
11800 [3.5]
1025 [484]
72
RGLE-10?BRM?
1
19200 [5.6]
9600 [2.8]
35800 [10.5]
15.1
12.5
875 [413]
71
2
24700 [7.2]
11100 [3.3]
1200 [566]
72
RGLE-12?ARM?
1
19600 [5.7]
9400 [2.8]
36000 [10.5]
15.1
12.5
925 [437]
71
2
25000 [7.3]
11000 [3.2]
1225 [578]
72
RGPE-07?BRQ?
1
19600 [5.7]
9400 [2.8]
35800 [10.5]
15.1
12.5
900 [425]
71
2
24800 [7.3]
11000 [3.2]
1225 [578]
72
RGPE-10?BRM?
1
19600 [5.7]
9400 [2.8]
35800 [10.5]
15.1
12.5
900 [425]
71
2
24800 [7.3]
11000 [3.2]
1225 [578]
72
RGPE-12?ARM?
1
19200 [5.6]
9600 [2.8]
35800 [10.5]
15.1
12.5
875 [413]
71
2
24700 [7.2]
11100 [3.3]
1200 [566]
72
RGRM-07?YBG?
1
18800 [5.5]
9600 [2.8]
34800 [10.2]
14
11
850 [401]
71
2
23700 [6.9]
11100 [3.3]
1200 [566]
72
RGRM-09?ZAJ?
1
19400 [5.7]
9400 [2.8]
35400 [10.4]
14.5
11.5
950 [448]
71
2
24400 [7.1]
11000 [3.2]
1225 [578]
72
RGRM-10?ZAJ?
1
19000 [5.6]
9600 [2.8]
35000 [10.3]
14.5
12
875 [413]
71
2
23600 [6.9]
11400 [3.3]
1150 [543]
72
RGRM-12?RAJ?
1
19600 [5.7]
9400 [2.8]
35600 [10.4]
15
12
925 [437]
71
2
24600 [7.2]
11000 [3.2]
1225 [578]
72
RGTM-07?RBG?
1
18600 [5.4]
9800 [2.9]
35000 [10.3]
15
12.5
800 [378]
71
2
23300 [6.8]
11700 [3.4]
1050 [495]
72
RGTM-09?ZAJ?
1
19900 [5.8]
9300 [2.7]
35600 [10.4]
15
12
975 [460]
71
2
24600 [7.2]
11000 [3.2]
1225 [578]
72
RGTM-10?RBJ?
1
19900 [5.8]
9300 [2.7]
35800 [10.5]
15
12
975 [460]
71
2
24800 [7.3]
11000 [3.2]
1225 [578]
72
Rev.
5/8/2012
➀
Highest sales volume tested combination required by D.O.E. test procedures.
[ ] Designates Metric Conversions