O P E R A T I O N
Options Window
350-9047 v3.0.1
DGy Model 201x User’s Guide
55
. . . . .
The DGy Control Panel will lose communication with the
DGy
201x
as soon as the restart procedure begins. If the IP address
of the
DGy 201x
has been changed, the new network settings
must be used to reconnect to it. After the connection has been
dropped, the WCP or Telnet session must be restarted.
S E R I A L P O R T S E T T I N G S
The current serial port baud rate is displayed and can be
changed in this section of the
Systems
tab. Available baud
rates range from 9600 baud to 115,200 baud. It is
recommended that the default baud rate, 115k baud, be used.
To change the serial port parameters:
~
Use the pull-down
Baud Rate
menu to set the baud rate
for the system’s RS-232 serial port. The default value is
115,200 baud.
~
Check the
Echo On
box to enable echo.
C L O C K S E T T I N G S
The
DGy 201x
uses an internal real-time clock to time stamp the
recordings.
The DGy system time and date can be set manually or
synchronized to the PC controlling the
DGy 201x
.
•
In the
Clock
section:
~
Click
Sync to PC
to load the PC’s local time into the
DGy
201x
’s temporary clock register.
~
Use the
Date
and
Time
up/down selectors to adjust the
date and time as necessary.
~
Identify the Time Zone the
DGy 201x
is located in by
using the drop down
Time Zone
box.
~
Click
Apply
to upload the new time setting into
DGy
201x
’s active clock register.
OR
~
Specify the time zone the
DGy 201x
is in by using the
drop down
Time Zone
box.
~
Use the entry boxes to manually set the
Date
and
Time
.
~
Click
Apply
to upload the new time setting into
DGy
201x
active clock register.
When
Apply
is clicked, a
Restart Warning
is displayed.
(
Figure 3-20
.) Click
No
to cancel the reboot and go
back to the old time and date values; click
Yes
to restart
the
DGy 201x
using the time and date values. A