O P E R A T I O N
Options Window
350-9047 v3.0.1
DGy Model 201x User’s Guide
53
. . . . .
G A M M A
Use this adjustment when the replay device has a different
gamma than that of the recorded image. An example would be
between a CRT and an LCD monitor. The range is from 0.5 to 2
in increments of 0.05.
T I M I N G L I S T
When the output
Mode
is set to
Freerun
, use the
Timing List
section of the
Output
tab to set the output format. Select the
required format from the drop down
Timing List
and click on the
Load
button.
The timing parameters associated with the format selected from
the
Timing List
are displayed in the
Video Output Timing
section
of the
Output
tab. Click the
Edit
box to make changes to the
parameters. Modified settings may then be saved to the
Timing
List
by selecting an unused entry in the list, between 100 and
160, and clicking the
Save
button. Unwanted entries to the
Timing List
can be deleted by selecting an entry and clicking
Delete
.
To return to the default autosync mode, set the output
Mode
to
Playback
.
V I D E O O U T P U T T I M I N G
Output timing parameters are displayed for the timing selected
from the
Timing List
. These parameters may be edited checking
the
Edit
box.
See
Making Timing Adjustments
on page 49 for more
information on timing parameters.
S Y N C T Y P E
Select the synchronization parameters as required.
S C A N R A T E
Set the
Scan Rate
parameters as required.
Note
The gamma of the input image recorded to disk is
preserved. The
Gamma
control does not apply to the
input image.
Important
Changing timing parameters should be done by
experienced video engineers only.