F I R M W A R E U P G R A D E
Manual Update Procedure
350-9047 v3.0.1
DGy Model 201x User’s Guide
146
. . . . .
7.
Type the command
bin
and press
ENTER
.
8.
Upload the firmware to the
DGy 201x
by issuing the
put
command followed by the firmware file name. The file name is
case sensitive and must be entered exactly. In the example
shown in
Figure C-8
the entry is:
put FWDGY.3.08.tgz
press
ENTER
.
9.
Type
ls
and press
ENTER
to verify that the file was uploaded.
10.
Type
bye
and press
ENTER
to exit ftp.
. . . . . . . . .
UPDATE FIRMWARE
11.
At the prompt, begin a new Telnet session.
Figure C-9
Update Firmware Command
12.
Type the
ufw
command and press
ENTER
.
13.
Type
y
to proceed or
n
to terminate the process.
After about 30 seconds, the connection to the host will be lost.
. . . . . . . . .
FTP FPGA FILE
14)
Re-establish the FTP connection as described in
Step 4.
above.
15.
Enter the user name
rgb
.
16.
Enter the password
spectrum
(case sensitive).
Caution
Failure to enter the
bin
command will cause the files
to be corrupted on transfer.
Important
Communications with the
DGy 201x
will be lost during
the installation process. This is normal and does not
indicate that there is a problem with the installation
process. This process approximately two minutes.
DO NOT