I N S T A L L A T I O N A N D S E T U P
Installation
350-9047 v3.0.1
DGy Model 201x User’s Guide
18
. . . . .
6.
Select a Control Method
— Control of the DGy can be through
either RS-232 serial or Ethernet connection. See
Appendix B
for details on establishing communication between a PC and the
DGy 201x
.
~
Serial Control
— To control
DGy 201x
using a terminal
emulation program (such as Hyperterminal or
Procomm), connect the COM port of the device to the
DGy 201x
RS-232 Port
. This enables
DGy 201x
control
through ASCII commands. For information on
DGy
201x
commands refer to the
Command Line Interface
chapter (page 85).
A straight through cable (typically 9-pin male-to-female
with one-to-one wiring) is required. For information on
RS-232 connection parameters refer to the
RS-232
Connector
section in Appendix A (page 129).
Launch Hyperterminal or other terminal emulator
software and set the communication parameters to:
• 115,200
Baud
• 8
Bits
•
1 Stop Bit
• No
Parity
•
XON/XOFF Flow Control
For information on setting up a Hyperterminal see
Appendix B,
Launching a Hyperterminal Window
on
page 131.
~
Ethernet Control
— To control the
DGy 201x
over a
network, connect an Ethernet cable from the LAN to the
DGy 201x
’s 100/1000 Base-T
Ethernet Port
. This
method allows use of a Telnet session or a standard
web browser to access
DGy 201x
’s internal
Web
Control Panel
. Ethernet is also ideal for controlling
multiple
DGy 201x
recorders.
Note
A PC can be connected directly to the
DGy 201x
Ethernet Port
without being connected to a network.
For this direct-connect method, use an Ethernet hub
or crossover cable. In Appendix A, refer to the
Ethernet Connector
section on page 128 for pinout
details.