Rev. 1.00, 09/03, page 434 of 704
Bit
Bit Name
Initial Value R/W
Description
4 FER 0
R/(W)
*
Framing Error
[Setting condition]
•
When the stop bit is 0
[Clearing condition]
•
When 0 is written to FER after reading FER =
1
In 2-stop-bit mode, only the first stop bit is
checked.
3 PER 0
R/(W)
*
Parity Error
[Setting condition]
•
When a parity error is detected during
reception
[Clearing condition]
•
When 0 is written to PER after reading PER =
1
2 TEND
1
R
Transmit
End
[Setting conditions]
•
When the TE bit in SCR is 0
•
When TDRE = 1 at transmission of the last bit
of a 1-byte serial transmit character
[Clearing conditions]
•
When 0 is written to TDRE after reading TDRE
= 1
•
When data is written to TDR
1 MPB 0
R
Multiprocessor
Bit
Stores the multiprocessor bit in the receive frame.
When the RE bit in SCR is cleared to 0, this bit is
not changed.
0
MPBT
0
R/W
Multiprocessor Bit Transfer
Sets the multiprocessor bit to be added to the
transmit frame.
Note:
*
Only 0 can be written, to clear the flag.
Summary of Contents for H8S/2437
Page 2: ...Rev 1 00 09 03 page ii of xxxviii ...
Page 8: ...Rev 1 00 09 03 page viii of xxxviii ...
Page 32: ...Rev 1 00 09 03 page xxxii of xxxviii ...
Page 38: ...Rev 1 00 09 03 page xxxviii of xxxviii ...
Page 168: ...Rev 1 00 09 03 page 130 of 704 ...
Page 336: ...Rev 1 00 09 03 page 298 of 704 ...
Page 402: ...Rev 1 00 09 03 page 364 of 704 ...
Page 454: ...Rev 1 00 09 03 page 416 of 704 ...
Page 512: ...Rev 1 00 09 03 page 474 of 704 ...
Page 562: ...Rev 1 00 09 03 page 524 of 704 ...
Page 648: ...Rev 1 00 09 03 page 610 of 704 ...
Page 672: ...Rev 1 00 09 03 page 634 of 704 ...
Page 732: ...Rev 1 00 09 03 page 694 of 704 ...
Page 742: ...Rev 1 00 09 03 page 704 of 704 ...
Page 745: ......
Page 746: ...H8S 2437 Group Hardware Manual REJ09B0059 0100Z ...